RoyalTek REV-2000 User Manual
Page 33
RoyalTek GPS Receiver REB-2000/REB-12R REV-2000 Operational Manual
16
Table 12 Query/Rate Control Data Format(See example 1.)
Name
Example
Units
Description
Message ID
$PSRF103
PSRF102 protocol header
Message
00
See Table 13
Mode
01
0=Set Rate, 1=Query
Rate
00
seconds Output – off=0,max=255
Cksum Enable
01
0=Disable Checksum, 1=Enable Checksum
Checksum *25
End of message termination
Table 13 Messages
Value Description
0 GGA
1 GLL
2 GSA
3 GSV
4 RMC
5 VTG
LLA Navigation Initialization
This command is used to initialize the
module for a warm start , by providing
current position(in latitude, longitude, and
altitude coordinates), clock offset, and time.
This enables the receiver to search for the
correct satellite signals at the correct signal
parameters . Correct initialization
parameters enable the receiver to acquire
signals quickly.
Table 14 contains the input values for the
following example: Start using known
position and time $PSRF104, 37.3875111,
-121.97232, 0, 95000, 237759, 922, 12,
3*3A
Table 14 LLA Navigation Initialization Data Format
Name
Example
Units
Description
Message ID
$PSRF104
PSRF104 protocol header
Lat
37.3875111
Degrees Latitude position (Range 90 to –90)
Lon
-121.97232
Degrees Longitude position (Range 180 to –180)
Alt 0
Meters
Altitude
position
CLK Offset
95000
Hz
Clock Offset of the Evaluation Unit1
Time Of Week
237759
Seconds GPS Time Of Week
Week No
922
GPS Week Number
Channel Count
12
Range 1 to 12
Reset Cfg
3
See Table 15
Checksum *3A
End of message termination
Use 0 for last saved value if available. If this is unavailable, a default value of 96,000 will be used.
Table 15 Reset Configuration
Hex Description
0x01
Data Valid – Warm /Hot Starts=1
0x02
Clear Ephemeris – Warm Start=1
0x04
Clear Memory – Cold Start =1
Development Data On/Off
Use this command to enable development
data information if you can not get the
commands accepted. Invalid commands
generate debug information that enables the
user to determine the source of the
command rejection. Common reasons for
input command rejection are invalid
checksum of parameter out of specified
range.
Table 16 contains the input values for the