( 49 / 84 )

Figure 3.20 Connecting to a 100-pin 0.5-mm-pitch foot pattern (part 2)

CAUTION

Notes on Connecting the Target System:

• Take care not to attach the converter board in a wrong direction. It may cause a fatal

damage to the emulation pod.

• The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal

iterations.

• The connector of the M3T-100LCC-QSD is guaranteed for only 20 insertion/

removal iterations.

(8) Connecting to a 100-pin 0.5-mm-pitch Foot Pattern (Part 2)

Here follows how to connect the emulation pod probe to a 100-pin 0.5-mm-pitch foot pattern on the
target system with the M3T-100LCC-QSD (not included). For details on the M3T-100LCC-QSD
(not included), refer to its user's manual.

(1) Mount the TQPACK100SD to the target system.
(2) Attach the TQSOCKET100SDG to the TQPACK100SD.
(3) Attach the M3T-100LCC-QSD to the TQSOCKET100SDG.
(4) Attach the CN2 side of the M30800T-PTC to the tip (CN2 side) of the pitch converter board

connected to the emulation pod probe.

(5) Attach the M30800T-PTC to the M3T-100LCC-QSD.

100-pin 0.5-mm-pitch (100P6Q-A) foot pattern

CN2 side

M30800T-PTC

M3T-100LCC-QSD (not included)

TQSOCKET100SDG

TQPACK100SD

Target system

No. 1 pin

(3)

(1)

(2)

(4)

(5)

Tip of pitch converter board

Tip of emulation pod probe