Pre l iminar y – Runco SP-50 User Manual
Page 71
Runco CinemaWall SP-42/-50/-60 Owner’s Operating Manual
61
PRE
L
IMINAR
Y
GRAS24
47 52 41 53 32 34
–
–
Sets the GAMMA to 2.4.
RHI
52 48 49
000
255
Adjusts red gain (highlight).
RLW
52 4C 57
000
255
Adjusts red offset (lowlight).
SHP
53 48 50
000
015
Adjusts the SHARPNESS.
STD
53 54 44
–
–
Executes FACTORY and WHITE BAL.
RESET commands.
TNT
54 4E 54
000
060
Adjusts the TINT.
SCREEN Menu Commands (Installer Adjust Mode)
CFR
43 46 52
000
255
Adjusts clock (PLL) frequency.
CPH
43 50 48
000
031
Adjusts PLL phase.
FRP
46 52 50
–
–
Executes IMAGE RESET.
HPS
48 50 53
064
191
Adjusts Horizontal position .
HSI
48 49 53
000
064
Adjusts Horizontal size (width).
VPS
56 50 53
064
191
Adjusts the Vertical position.
VSI
56 53 49
000
064
Adjusts Vertical size (height).
SET-UP Menu Commands (Installer Adjust Mode)
SVL
53 56 4C
000
020
Adjusts the sub-volume.
OPTION Menu Commands (Installer Adjust Mode)
BPIS01
42 50 49 53 30 31
–
–
Sets BANNER PIP input to INPUT1.
BPIS02
42 50 49 53 30 32
–
–
Sets BANNER PIP input to INPUT2.
BPPS00
42 50 50 53 30 30
–
–
Sets BANNER PIP to OFF.
BPPS01
42 50 50 53 30 31
–
–
Sets BANNER PIP position to TOP.
BPPS02
42 50 50 53 30 32
–
–
Sets BANNER PIP position to
MID-HIGH.
BPPS03
42 50 50 53 30 33
–
–
Sets BANNER PIP position to
MID-LOW.
BPPS04
42 50 50 53 30 34
–
–
Sets BANNER PIP position to BOT-
TOM.
BSL
42 53 4C
000
255
Adjusts BLUE sidebar level.
CLMS00
43 4C 4D 53 30 30
–
–
Sets the ISF SETTING to NORMAL.
Table 6-1. Serial Commands (continued)
Command
Value Range
Description
ASCII
HEX
Minimum Maximum
Notes:
1. When making input-specific adjustments such as to image quality, screen position/size or audio
sub-volume, select the input you wish to affect before making such adjustments.
2. These settings are not stored in memory.