beautypg.com

Power supply, Ac supply (100, 115 or 230 vac), Dc supply (-48 vdc) – RAD Data comm ASM-20 User Manual

Page 46: Power supply with redundancy, 3 power supply

background image

Chapter 5 Card-Cage Version

ASM-20 Installation and Operation Manual

5-4 Power

Supply

5.3 Power

Supply

Power is supplied to the ASM-20/R card from the ASM-MN-214 power supply via
the chassis. Each ASM-20/R card has two fuses, which protect the entire system
against power failure resulting from a short circuit in one card.
The ASM-MN-214 card cage can accept both AC or DC power supplies. LED
indicators located on the ASM-MN-214 front panel (see

Figure 5-3

) show activity

when the power supply is connected to the mains plug. The power supply

supports the full card cage with any combination of cards.

AC Supply (100, 115 or 230 VAC)

The AC power supply of the ASM-MN-214 is 100, 115 or 230 VAC, ±10%,

47 to 63 Hz.

DC Supply (-48 VDC)

The DC power supply is -36 to -72 VDC. It uses a DC/DC converter module to
provide the power required for the cards.

Power Supply with Redundancy

This special ordering option is equipped with two separate power supplies,
operating together and sharing the load of the whole card cage. If either of the
power supplies fails, the other one will continue to supply power to the full card
cage.
Two LED indicators show activity of each power supply. They both light when
mains power is provided.

It is possible to combine AC and DC power supplies in the same cage.

Note