Chapter 2 Installation and Setup

ASM-20 Installation and Operation Manual

2-4

Setting Internal Jumpers and Switches

Table 2-1. ASM-20 Strap Selection Settings

Jumper and
Switch Identity

Function Possible

Settings**

J1

V54 DIS

Prevents activation of remote V.54 loops.

EN

DIS

J2
CARRIER

Selects the transmit carrier mode. When ON, transmit
carrier is constantly ON. When CNTRL, transmit carrier is

ON only when RTS is High. In X.21, RTS is replaced by the

CONTROL signal.

ON

CNTRL

J3

XMT CLK

Selects the transmit timing signal from either: internal clock,

external clock or receive clock and enables working in
Asynchronous mode.

INT

EXT

RCV

ASY

J4
RTS-CTS

DLY (ms)

Selects the delay between RTS and CTS.

0

9

70

J6

SW. EN.

Enables activation of DIG, ANA and REM loopbacks via the

front panel push buttons.

ON

OFF

J7

RLB DTE

Enables Remote Loopback command from the DTE.

EN

DIS

J8

ALB DTE

Enables Analog Loopback command from the DTE.

EN

DIS

J9

RCV LVL

Selects the receiver sensitivity level required.

LOW

HIGH

J10

RCV IMP

Selects receive line impedance.

150

HIGH

J11

RPF*

Enables the Remote Power Failure feature.

ON

OFF

J12

XMT LVL

Selects the transmit output level to the line.

0 dBm

-6 dBm

J13

XMT IMP

Selects the transmit line impedance.

150

LOW

J14

CHASS

The CON setting connects Signal Ground to Chassis

Ground. The DIS setting disconnects them.

DIS

CON

* Only for standalone option