RAD Data comm ASM-20 User Manual
Page 22
![background image](/manuals/200379/22/background.png)
Chapter 1 Introduction
ASM-20 Installation and Operation Manual
1-8
Technical Specifications
02-Aug-2005 10:47
Diagnostics
(Complies with the
V.54 Standard)
Digital Loopback
Local (DIG), activated by a manual switch
Remote (REM), activated by a manual switch or
by a control signal from the DTE interface
connector
Analog Loopback
Local (ANA), activated by a manual switch or by a
control signal from the DTE interface connector
Pattern
Test pattern activated by manual switch
Timing Elements
Receive Clock
Derived from the receive signal
Transmit Clock
Derived from 3 alternative sources:
Internal oscillator
External from the DTE
Loop clock derived from the receive signal
Indicators
Power
PWR (green)
Request to Send
RTS (yellow)
Transmit Data
TD (yellow)
Receive Data
RD (yellow)
Data Carrier Detect
DCD (yellow)
Test
TEST (red)
Bit errors
Err (yellow)
Electrical
Power Supply
115 or 230 V (± 10%)
47 to 63 Hz; 5W
-48 VDC or 24 VDC
Physical
ASM-20 Modem
Height: 44 mm/ 1.7 in
Width: 215 mm/ 8.5 in
Depth: 243 mm/ 9.6 in
Weight: 1.1 kg / 2.4 lb
ASM-20-R Card
Dimensions: Fits ASM-MN-214 modem rack
Weight: 290 gm / 10.1 oz
Environment
Temperature
0° - 50°C / 32° - 122°F
Humidity
Up to 90%, non-condensing