22

Regency E21 Gas Fireplace Insert

MAINTENANCE

INSTRUCTIONS

1) Always turn the gas valve to off before

cleaning. For relighting, refer to lighting

instructions. Keep the burner and control

compartment clean by brushing and

vacuuming at least once a year.

When cleaning the logs, use a clean soft

paint brush as the logs are fragile and easily

damaged.

2) Clean (never when unit is hot) appliance,

door and louvers with a damp cloth. Never

use an abrasive cleaner. The gold louvers

(and optional gold door) may be scratched

if abrasives are used to clean them.

The heater is fi nished in a heat resistant

paint and should only be refi nished with

heat resistant paint (not with wall paint).

Regency uses StoveBrite Paint - Metallic

Black #6309.

3) Make a periodic check of burner for proper

position and condition. Visually check the

fl ame of the burner periodically, making sure

the fl ames are steady; not lifting or fl oating.

If there is a problem, call a qualifi ed service

person.

4) The appliance and venting system must be

inspected before use, and at least annually,

by a qualifi ed fi eld service person, to ensure

that the fl ow of combustion and ventilation

air is not obstructed.

During the annual service call, the burners

should be removed from the burner tray

and cleaned. Replace the embers but do

not block the pilot.

5) Keep the area near the appliance clear and

free from combustible materials, gasoline

and other fl ammable vapours and liquids.

6) Each time the appliance is lit, it may cause

condensation and fog the glass. This

condensation and fog is normal and will

disappear in a few minutes as the glass

heats up.

Never operate the appliance without

the glass properly secured in place

or with the door open.

7) Verify proper operation after servicing.

8) Periodically check the pilot fl ames, see

the diagrams on page 11. If you have

an incorrect fl ame pattern, contact your

Regency dealer for further instructions.

MAINTENANCE

LOG REPLACEMENT

The unit should never be used with broken logs.

Turn off the gas valve and allow the unit to cool

before opening door to carefully remove the

logs. The pilot light generates enough heat to

burn someone. If for any reason a log should

need replacement, you must use the proper

replacement log. The position of these logs

must be as shown in the diagram under Log

Installation.

NOTE: Improper positioning of logs may

create carbon build-up and will alter

the unit’s performance which is not

covered under warranty.

GLASS GASKET

If the glass gasket requires replacement use

7/8" fl at glass gasket (Part # 936-243) for the

Bay Front and for the Flush Front.

GOLD-PLATED

ACCESSORIES

The 24 carat gold plated fi nish on the accessories

requires little maintenance, and need only be

cleaned with a damp cloth. DO NOT use abrasive

materials or chemical cleaners, as they may

harm the fi nish and void the warranty.

Clean any fi ngerprints off before turning the

unit on. If the top louvers start to discolour,

check the door gasket seal and replace if

necessary.

AUTOMATIC

CONVECTION FAN

OPERATION

The fan operates automatically, turn the knob on

the side of the faceplate to adjust to the desired

speed. The fan will turn on as the stove comes

up to operating temperature. After the unit has

been turned off and the unit cooled to below a

useful heat output range the fan will shut off

automatically.

NORMAL OPERATING

SOUNDS OF GAS

APPLIANCES

It is possible that you will hear some sounds

from your gas appliance. This is perfectly normal

due to the fact that there are various gauges

and types of steel used within your appliance.

Listed below are some examples. All are

normal

operating sounds and should not be considered

as defects in your appliance.

Blower:

Regency gas appliances use high tech blowers

to push heated air farther into the room. It is not

unusual for the fan to make a "whirring" sound

when ON. This sound will increase or decrease

in volume depending on the speed setting of

your fan speed control.

Burner Tray:

The burner tray is positioned directly under the

burner tube(s) and logs and is made of a different

gauge material from the rest of the fi rebox and

body. Therefore, the varying thicknesses of steel

will expand and contract at slightly different

rates which can cause "ticking" and "cracking"

sounds. You should also be aware that as there

are temperature changes within the unit these

sounds will likely re-occur. Again, this is normal

for steel fi reboxes.

Blower Thermodisc:

When this thermally activated switch turns ON

it will create a small "clicking" sound. This is the

switch contacts closing and is normal.

Pilot Flame:

While the pilot fl ame is on it can make a very

slight "whisper" sound.

Gas Control Valve:

As the gas control valve turns ON and OFF, a

dull clicking sound may be audible, this is normal

operation of a gas regulator or valve.

Unit Body/Firebox:

Different types and thicknesses of steel will

expand and contract at different rates resulting

in some "cracking" and "ticking" sounds will be

heard throughout the cycling process.

WARNING: CHILDREN AND ADULTS

SHOULD BE ALERTED TO THE

HAZARDS OF HIGH SURFACE

TEMPERATURE AND SHOULD

STAY AWAY TO AVOID BURNS OR

CLOTHING IGNITION. YOUNG

CHILDREN SHOULD BE CAREFULLY

SUPERVISED WHEN THEY ARE IN THE

SAME ROOM AS THE APPLIANCE.

CAUTION: ANY SAFETY SCREEN OR

GUARD REMOVED FOR SERVICING AN

APPLIANCE MUST BE REPLACED PRIOR

TO OPERATING THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE

MATERIAL SHOULD NOT BE PLACED

ON OR NEAR THE APPLIANCE.

This manual is related to the following products: