beautypg.com

Part 2 - installation / service instructions – Raypak Versa 105B User Manual

Page 9

background image

PART 2 - INSTALLATION / SERVICE INSTRUCTIONS

SECTION 1
RECEIVING EQUIPMENT

On receipt of your equipment it is suggested that you

visually check for external damage to the carton. If the
carton is damaged, a note should be made on the Bill of
Lading when signing for equipment. Remove the heater
from the carton and if it is damaged, report the damage
to the carrier immediately.

On occasion, we ship some items loose. Be sure that

you receive the number of packages indicated on the Bill
of Lading.

When ordering parts, you must specify model and

serial number of heater. When ordering under warranty
conditions, you must also specify date of installation.

The manufacturer recommends that this manual be

reviewed thoroughly before installing your pool/spa
heater. If there are any questions that this manual does
not answer, please contact the factory or your local
representative.

SECTION 2
GENERAL SPECIFICATION

These heaters are design certified and tested under

the requirements of ANSI Z21.56/CSA 4.7 American
National Standard / CSA Satndard for gas-fired Pool
Heaters.

The heater is interchangeable and can be used either

indoor or outdoors. The appropriate top designated for
that type of use is required. If desired, the top can be
changed at a later date to change from outdoor to indoor
or vice versa. Millivolt heaters contain a self-generating
electrical system operating between .25 and .75 volts.

AMBIENT TEMPERATURE RATING OF HEATER COM-
PONENTS

Millivolt Heater with Honeywell Gas Valve

+32°F to+175°F

Millivolt Heater with Robertshaw Gas Valve

0°F to +175°F

Electronic Ignition Heaters*

-32°F to +175°F

*Requires 120V or 240V power supply

Rated inputs suitable for up to 2000 feet elevation. For

elevations above 2000 feet, reduce input 4% for each
1000 feet above sea level, as high elevation reduces
combustion performance.

SECTION 3
INSTALLATION INSTRUCTIONS

IMPORTANT NOTICE

These instructions are intended for the use of quali-

fied personnel only, specifically trained and experienced
in the installation of this type of heating equipment and
related system components. Installation and service
personnel may be required by some states to be li-
censed. If your state is such, be sure your contractor
bears the appropriate license. Persons not qualified
shall not attempt to fix this equipment nor attempt
repairs according to these instructions.

WARNING: Improper installation, adjustment, altera-
tion, service or maintenance may damage the equip-
ment, create a hazard resulting in asphyxiation, explo-
sion or fire, and will void the warranty.

CODE REQUIREMENTS

NOTE: The heater should not be located in an area
where possible water leakage will result in damage to
the area adjacent to the appliance or to the structure.
When such locations cannot be avoided, it is recom-
mended that a suitable drain pan, adequately drained,
be installed under the appliance. The pan must not
restrict combustion air flow.

Installation must be in accordance with local codes,

or, in the absence of local codes, with the latest editions
of the National Fuel Gas Code, ANSI Z223.1, and the
National Electrical Code, ANSI/NFPA 70.

BASE INSTALLATION

Heater must be mounted on a level surface. It can

be installed on combustible flooring. Heaters must not
be installed on carpeting.

WARNING: Do not install within 3 feet of a Heat Pump
or an outdoor condensing unit. Strong air intake from
these equipment can disturb the combustion process
and cause damage or personal injury.

9

CALIFORNIA PROPOSITION 65

WARNING:

This product contains chemicals known to the

State of California to cause cancer, birth defects or
other reproductive harm.