Page 19

background image

C

HAPTER

4: I

NSTALLATION

11

P

REPARE

D

EVICES

Devices to be controlled by Paragon through ConsoleSwitch must be set at the following communications settings.
Before proceeding, check all devices that you wish to connect, and ensure that they have been set correctly. Consult

your device’s user manual to change the communications parameters if they do not match.

Terminal Emulation:

VT100

Baud Rate:

9600

Data Bits:

8

Stop Bits:

1

Parity:

None

C

ONNECTING

S

ERIAL

D

EVICES

1. For each device that you wish to control via ConsoleSwitch, connect an appropriate Raritan-supplied

nulling serial adapter (See Chapter 2: Introduction - Related Products) that fits the gender and form factor

of the device’s serial console port – sometimes labeled “Admin”, “COM”, “Serial”, “RS232”, or “AUX”.

2. Using standard, straight-through UTP cable of an appropriate length (see Chapter 3: Cabling

Requirements - ConsoleSwitch Cabling), connect each nulling serial adapter to a Device Port (labeled 1
through 32) on the back of ConsoleSwitch.


See Figure 5: Device Cabling to ConsoleSwitch (in previous section) for clarification.