System exclusive message, Midi implementation n system exclusive message, Luniversal non-realtime system exclusive message – Roland MIDI Implementation SH-01 User Manual
Page 7: Ldata transmission
7
MIDI Implementation
n
System Exclusive Message
Status
Data byte
Status
F0H
iiH, ddH, ......,eeH
F7H
F0H:
System Exclusive Message status
ii = ID number:
An ID number (manufacturer ID) to indicate the manufacturer
whose Exclusive message this is. Roland’s manufacturer ID
is 41H. ID numbers 7EH and 7FH are extensions of the MIDI
standard; Universal Non-realtime Messages (7EH) and Universal
Realtime Messages (7FH).
dd,...,ee = data:
00H - 7FH (0 - 127)
F7H:
EOX (End Of Exclusive)
Universal Non-realtime System Exclusive Messages and Data Set 1 (DT1) are the only
System Exclusive messages transmitted by the SH-01.
l
Universal Non-realtime System Exclusive Message
m
Identity Reply Message (SH-01)
Receiving Identity Request Message, the SH-01 send this message.
Status
Data byte Status
F0H
7EH, dev, 06H, 02H, 41H, 41H, 02H, 00H,
00H, 00H, 03H, 00H, 00H
F7H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (Universal Non-realtime Message)
dev
Device ID (dev: 10H - 1FH)
06H
Sub ID#1 (General Information)
02H
Sub ID#2 (Identity Reply)
41H
ID number (Roland)
41H 02H
Device family code
00H 00H
Device family number code
00H 03H 00H 00H
Software revision level
F7H
EOX (End of Exclusive)
l
Data Transmission
m
Data set 1 DT1 (12H)
Status
Data byte Status
F0H
41H, dev, 00H, 00H, 41H, 12H, aaH, bbH,
ccH, ddH, eeH, ... ffH, sum
F7H
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
dev
Device ID (dev: 00H - 1FH, 7FH)
00H
Model ID #1 (SH-01)
00H
Model ID #2 (SH-01)
41H
Model ID #3 (SH-01)
12H
Command ID (DT1)
aaH
Address MSB: upper byte of the starting address of the data
to be sent
bbH
Address:
upper middle byte of the starting address of
the data to be sent
ccH
Address:
lower middle byte of the starting address of the
data to be sent
ddH
Address LSB:
lower byte of the starting address of the data to
be sent.
eeH
Data:
the actual data to be sent. Multiple bytes of
data are transmitted in order starting from the
address.
:
:
ffH
Data
sum
Checksum
F7H
EOX (End Of Exclusive)
* The amount of data that can be transmitted at one time depends on the type of
data, and data will be transmitted from the specified starting address and size. Refer
to the address and size given in “Parameter Address Map” (p. 8).
* Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.