Rinnai Corporation RHFE-750ETRA

Application

Vented gas fireplace heater; Inbuilt only; for residential installation, commer-
cial setting, or manufactured home; not designed for installation in a solid-fuel
burning fireplace

General Description

Inbuilt convector, glass and steel fronted, ceramic log space heater with
forced convection and power flue system

Operation

Push button electronic / remote control

Gas Connection

Flex line is 3/8 inch flare nut;
ball valve is 1/2 inch female x 3/8 inch flare

Gas Control

Electronic

Burners Flame

burners

Temperature Control

Electronic thermostat

Logs Ceramic

Ignition System

Electronic spark ignition

Flue System

The flue must be terminated to atmosphere. Only flue components listed with
the appliance’s certification can be used. Warranty will be voided if non-listed
components are installed.

Fan

(134 to 212 CFM)

Weight

150 lb (68 kg)

Electrical Connection

AC 120V, 60 Hz

Certification

CSA certified according to ANSI Z21.88, CSA 2.33

AFUE

79% NG; 81% LP (up to 83% with extended vent of 7.2 ft [2.2 m] and no
elbows)

Venting

Twin flue: maximum 6.5 ft with 2 elbows
Concentric: maximum 33 ft with 3 elbows

Specifications

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.

Natural Gas

Propane Gas

Minimum supply gas pressure

4.3 in (109 mm) W.C.

9.8 in (249 mm) W.C.

Maximum supply gas pressure

10.5 in (267 mm) W.C.

13.0 in (330 mm) W.C.

Manifold test pressure

Factory Set

Factory Set

BTU/hour input

Natural Gas: Low - 11,000 BTU/h; High - 29,000 BTU/h
Propane:

Low - 11,000 BTU/h; High - 28,000 BTU/h

BTU/hour output

Natural Gas: Low - 8,635 BTU/h; High - 21,900 BTU/h
Propane:

Low - 8,855 BTU/h; High - 21,840 BTU/h