beautypg.com

Installation – Regency P48 User Manual

Page 34

background image

Regency P48 Zero Clearance Direct Vent Gas Fireplace

34

CONVERSION KIT FROM NATURAL GAS TO PROPANE MODEL #370-969

FOR P48 USING SIT 820 NOVA GAS VALVE

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

5) Pull off the pilot

cap to expose the
pilot orifice.

6) Unscrew the pilot orifice with the allen key

and replace with the LP pilot orifice in the kit
and replace pilot cap.

8) Reinstall new burner orifice LP stamped #47

and tighten.

9) Remove and discard the 3 pressure regu-

lator mounting screws (A), pressure regu-
lator tower (B) and diaphragm (C).

10) Insure that the rubber gasket (D) is properly

positioned and install the new HI/LO pres-
sure regulator assembly to the valve using
the new screws (E) supplied with the kit.
Tighten screws securely.

11) Reverse steps 4) to 1).

12) Attach clear label "This unit has been con-

verted to Propane" near or on the serial #
decal. Attach white label "This valve has
been converted from NG to LPG using SIT
conversion Kit Code 0.907.202" onto the
valve.

13) Replace yellow "Natural Gas" label with red

"Propane" label

7) Remove burner orifice with a 1/2" wrench

and discard. Use another wrench to hold
on to the elbow behind the orifice.

Burner Orifice

Conversion Kit Contains:

Qty. Part #

Description

1

910-018

SIT Conversion Kit-50%
Turndown LP

1

910-037

LP Injector (Pilot Orifice)

1

904-434

Burner Orifice #47

1

908-255

Decal "Converted to Propane"

1

908-529

5/32" Allen Key

1

918-032

Instruction Sheet

1) Remove the louvers and trim kit. Remove the

front door.

2) Remove the logs, embers.

3) Remove the grate by lifting straight up.

Diagram 1: Remove the left screw and then
slide the burner assembly away from the
orifice and lift out.

4) Remove the burner assembly by removing

the 1 Phillips head screw and then slide the
burner assembly away from the orifice and
lift out.

14) Check for gas leaks.

15) Check inlet and outlet pressures.

16) Check operation of flame control.

17) Check for proper flame appearance and

glow on logs.

INSTALLATION

This manual is related to the following products: