Regency P48 Zero Clearance Direct Vent Gas Fireplace
12
VENTING
Regency Direct Vent System (Flex) Horizontal
Terminations Only
These venting systems, in combination with the P48 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock
Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 11.
Regency Direct Vent (Flex) System Termina-
tion Kit (Part# 946-615) includes all the parts
needed to install the P48 with a maximum run
of 4 feet.
1) 8" dia. flexible liner (4 ft. length)
2) 5" dia. flexible liner (4 ft. length)
3) spring spacers (4)
4) thimble (2)
5) AstroCap XL termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point, Stainless Steel (4)
10) vinyl siding standoff
If longer runs are needed, the Regency Direct
Vent system (Flex) Part# 946-616 includes all
the parts needed to install the P48 with a
maximum 10' run.
1) 8" dia. flexible liner (10 ft. length)
2) 5" dia. flexible liner (10 ft. length)
3) spring spacers (7)
4) thimble (2)
5) AstroCap XL termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point, Stainless Steel (4)
10) vinyl siding standoff
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
3) If you are installing the P48 into a Regency Mantel Kit, use the minimum horizontal vent height (centre-line of 43"). Remember
to include the mantel base in your calculations and to maintain the 2-1/2" clearance to the underside of the mantel top.