Installation – Regency P48 User Manual
Page 16
Regency P48 Zero Clearance Direct Vent Gas Fireplace
16
INSTALLATION
Horizontal Venting with Three (3) 90
o
Elbows
Option V
H V + V1
H + H1
A)
2' Min.
1' Max.
3' Min.
4' Max.
B)
3' Min.
2' Max.
4' Min.
5' Max.
C)
4' Min.
3' Max.
6' Min.
6' Max.
D)
5' Min.
4' Max.
8' Min.
7' Max.
E)
6' Min.
5 Max.
10' Min. 8' Max.
F)
7' Min.
6' Max.
12' Min. 9' Max.
Vertical Venting with Two (2) 90
o
Elbows
Option V
H
V + V1
A)
1' Min.
4' Max.
2' Min.
B)
2' Min.
5' Max.
3' Min.
C)
3' Min.
6' Max.
4' Min.
D)
4' Min.
7' Max.
5' Min.
E)
5' Min.
8' Max.
6' Min.
Vertical Venting with Two (2) 90
o
Elbows
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is re-
quired.
Option H + H1 V
A)
2' Max. 2' Min.
B)
3' Max. 3' Min.
C)
4' Max. 4' Min.
D)
5' Max. 5' Min.
E)
6' Max. 6' Min.
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and
max. 6 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is re-
quired.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
For additional vertical vent-
ing with 2 x 90
o
elbows,
refer to page 18.
With these options,
max. total pipe length
is 30 feet with min. of
12 feet total vertical
and max. 9 feet total
horizontal.
Please note min. 1
foot between 90
o
elbows is required.