beautypg.com

Important warning, Connecting to the 15-pin connector – RoboteQ AX2850 User Manual

Page 18

background image

AX2550 Quick Start

18

AX2550 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

the Controller” on page 29 for more information about batteries and other connection
options.

Important Warning

Do not rely on cutting power to the controller for it to turn off if the Power Control is
left floating. If motors are spinning because the robot is pushed are pushed or
because of inertia, they will act as generators and will turn the controller, possibly in
an unsafe state. ALWAYS ground the Power Control wire to turn the controller Off
and keep it Off.

Important Warning

The controller includes large capacitors. When connecting the Motor Power Cables,
a spark will be generated at the connection point. This is a normal occurrence and
should be expected.

Connecting to the 15-pin Connector

The controller’s I/O are located on it’s standard 15-pin D-Sub Connector. The functions of
some pins varies depending on controller model and operating mode. Pin assignment is

found in the table below.

Pin

Signal

RC Mode

RS232 Mode

Analog Mode

1

2A Digital Output C (same as pin 9)

2

TxData

3

RC Ch1

RxData

Unused

4

RC Ch 2

Digital Input F

5

Ground Out

6

Ground In

(Unused on RevB Hardware)

7

+5V In

(Unused on RevB Hardware)

8

Digital Input E (Not available when Encoder module is present)

and Analog Input 4 (on RevB hardware only)

9

2A Digital Output C (same as pin 1)

10

Analog Input 2

11

Analog Input 1

12

Analog Input 3 (on RevB hardware)

13

Ground Out

14

+5V Out (100mA max.)

15

Emergency Stop or Invert Switch input