Important warning, Connecting to the 15-pin connector – RoboteQ AX2850 User Manual
Page 18
AX2550 Quick Start
18
AX2550 Motor Controller User’s Manual
Version 1.9b. June 1, 2007
the Controller” on page 29 for more information about batteries and other connection
options.
Important Warning
Do not rely on cutting power to the controller for it to turn off if the Power Control is
left floating. If motors are spinning because the robot is pushed are pushed or
because of inertia, they will act as generators and will turn the controller, possibly in
an unsafe state. ALWAYS ground the Power Control wire to turn the controller Off
and keep it Off.
Important Warning
The controller includes large capacitors. When connecting the Motor Power Cables,
a spark will be generated at the connection point. This is a normal occurrence and
should be expected.
Connecting to the 15-pin Connector
The controller’s I/O are located on it’s standard 15-pin D-Sub Connector. The functions of
some pins varies depending on controller model and operating mode. Pin assignment is
found in the table below.
Pin
Signal
RC Mode
RS232 Mode
Analog Mode
1
2A Digital Output C (same as pin 9)
2
TxData
3
RC Ch1
RxData
Unused
4
RC Ch 2
Digital Input F
5
Ground Out
6
Ground In
(Unused on RevB Hardware)
7
+5V In
(Unused on RevB Hardware)
8
Digital Input E (Not available when Encoder module is present)
and Analog Input 4 (on RevB hardware only)
9
2A Digital Output C (same as pin 1)
10
Analog Input 2
11
Analog Input 1
12
Analog Input 3 (on RevB hardware)
13
Ground Out
14
+5V Out (100mA max.)
15
Emergency Stop or Invert Switch input