RoboteQ AX2850 User Manual
Page 159
AX2550 Motor Controller User’s Manual
159
RS232 Encoder Command Set
Example:
*84
Read value of parameter at address hex 84
01
Controller replies, value is 01
Modify parameter
Syntax:
*mm nn
Reply:
+ if command was executed successfully
- if error
Where
mm= parameter address
nn= new parameter value
Examples:
*84 03
Store 03 into parameter at address hex 84
Notes:
All parameters and values are expressed with 2 hexadecimal digits.
The table below lists maps the few relevant parameters that can be accessed using this
command.
TABLE 31. Encoder Registers
Address
Parameter Description
Size
Access
*84
Encoder Hardware ID Code
1 byte
Full
*85
Switches Status
1 byte
Full
*86
Speed or Distance 1 (depending on operating mode)
1 byte
Full
*87
Speed or Distance 2 (depending on operating mode)
1 byte
Full
*88
Counter Read/Write Mailbox MSB (bits 31 to 24)
4 bytes
Full
*89
Counter Read/Write Mailbox (bits 23 to 16)
*8A
Counter Read/Write Mailbox (bits 15 to 8)
*8B
Counter Read/Write Mailbox LSB (bits 7 to 0)
*8C
Counter 1 MSB (bits 31 to 24)
4 bytes
Limited
*8D
Counter 1 (bits 23 to 16)
*8E
Counter 1 (bits 15 to 8)
*8F
Counter 1 LSB (bits 7 to 0)
*90
Counter 2 MSB (bits 31 to 24)
4 bytes
Limited
*91
Counter 2 (bits 23 to 16)
*92
Counter 2 (bits 15 to 8)
*93
Counter 2 LSB (bits 7 to 0)
*94
Destination Register 1 MSB (bits 31 to 24)
4 bytes
Full
*95
Destination Register 1 (bits 23 to 16)
*96
Destination Register 1 (bits 15 to 8)
*97
Destination Register 1 LSB (bits 7 to 0)