Acceleration, Input switches function – RoboteQ AX2850 User Manual
Page 147
AX2550 Motor Controller User’s Manual
147
Accessing & Changing Configuration Parameter in Flash
Acceleration
Address:
^03
Access:
Read/Write
Effective:
After Reset or ^FF
This parameter configures the rate at which the controller internally changes the command
value from the one it was to the one just received.
Input Switches Function
Address:
^04
Access:
Read/Write
Effective:
After Reset or ^FF
This parameter enables and configures the effect of the controller’s Digital Inputs and other
settings.
Bit
Definition
See pages
7:0
0 = very slow
1 = slow
(2) = medium-slow (default)
3 = medium
4 = fast
5 = fastest
See “Programmable Acceleration”
on page 47 for complete list of
acceptable values
Bit
Definition
See pages
1:0
Enable and
Configure
Invert/Estop
(00) = Input Disabled (default)
01 = Input as Emergency Stop
10 = Disabled
11 = Input as Invert Command
2
Output C when
Motor On
(0) = No Action (default)
1 = Output C On when either motor is On
3
Encoder Safety
(0) = No Action (default)
1 = Disables Controller if Encoder detects
no movement while power is applied to
the motors