beautypg.com

Programming the fastrad – Nortel Networks FastRad User Manual

Page 20

background image

10

FastRAD Installation Guide

Programming
the FastRAD

Before you start, make sure you have completed the

FastRAD

Programming Record

found at the end of this guide. This

record must include the System ID, Auto-answer line number
and Alarm reporting line number.

Table 2 shows the different programming parameters and their
default values. If your programming information does not
specify a value for one of the fields, assign it to the default
value.

Note

: You must program the Required fields for the FastRAD to

operate. Also program any Optional fields that apply to your
system. Auto-answer should be set to ON if unassisted remote
access to the FastRAD is desired.

Table 2 – Programming parameters and default values

Programming Field

Range

Required / Optional

Default

Password

8 to 10 digits

Required

none

System ID

Up to 10 digits

Optional

blank

Auto-answer line number

1 - 999

Required for auto-answering

Line 001

Alarm reporting line number

1 - 999

Required for alarm reporting

Line 001

Local baud rate

300/1200/2400/4800/
9600/19200

Optional

9600

Auto report alarms

ON, OFF

Optional

OFF

Alarm number 1

up to 16 digits

Optional

blank

Alarm number 2

up to 16 digits

Optional

blank

Retry delay

1 - 99 minutes

Optional

15 minutes

Number of retries

0 - 9

Optional

5

Alarm reporting baud rate

Low/Medium/High

Optional

High

Alarm reporting parity

None/Odd/Even

Optional

None

Auto-answer

ON, OFF

Optional

OFF

Answer delay

6 to 60 seconds

Optional

18 seconds

855601 Book : 855601 Guide Page 10 Wednesday, October 29, 1997 4:06 PM