Line attenuation

Line voltage (remote-powered)

Attenuation can be 0 to 41 dB.

DNT statistics via the front panel or Q1

Signal qualities of the selected 15-minute periods (4 periods with front panel
menus and 100 with Q1) and 24-hour periods (4 periods with front panel menus
and 30 with Q1) and since the last reset, according to Rec. G.826, are indicated
by the quality parameters in Table 15.

System counters via Q1

Number of CPU resets and the time passed since the last reset.

Table 15.

Statistics values via Q1

Information

Abbreviation and/or
ratio

Description

Total time

TT

Time passed since the last reset.

Unavailability time

UAT

(Rx, Tx)

Time during which severely errored seconds have
occurred.

Errored seconds

ES

(Rx, Tx)

Number of errored seconds.

Severely errored seconds

SES

(Rx, Tx)

Number of seconds during which

30% blocks

are errored.

Background block errors

BBE

(Rx)

Number of errored blocks except blocks during
severely errored seconds and unavailable time.

The block size depends on the used line rate.

Unavailability time ratio

UATR

(Rx, Tx)

Ratio of unavailability time to the total time during
the last 15 minutes or 24 hours.

Errored seconds ratio

ESR

(Rx, Tx)

Ratio of errored seconds to the total of seconds in
the available time during the last 15 minutes or 24
hours.

Severely errored seconds
ratio

SESR

(Rx, Tx)

Ratio of severely errored seconds to the total of
seconds in the available time during the last 15
minutes or 24 hours.

Background block error
ratio

BBER

(Rx)

Ratio of background block errors to the total of
blocks during the last 15 minutes or 24 hours,
except blocks during severely errored blocks and
unavailable time.