Smart-ag mating connectors, A.2.2 smart-ag connector and cable requirements – Novatel GNSS Receiver and Antenna SMART-AG User Manual
Page 63

SMART-AG User Manual Rev 5
63
A.2.2
SMART-AG Connector and Cable Requirements
Custom cables for installing your SMART-AG can be created using he following guidelines:
• Wire size: must be 0.5 mm-1.25 mm (20-16 AWG)
• Batt + connection must be protected by 5A fast blow fuse
• Serial data signals (TxD, RxD, signal ground) must be run in shielded cable.
Connect shields to ground at SMART-AG end only
• CAN signal conductors must be twisted (40 twists/m, 12 twists/ft)
• Use only the recommended mating connectors listed below. Use only gold plated
pins
The connector used in the SMART-AG is an “AMPSEAL” dust and water sealed type produced by
Tyco. The following part numbers pertain to the mating connector required to make connections to the
SMART-AG. These numbers are provided for information only and are not available from NovAtel as
separate parts.
Table 7: SMART-AG Mating Connectors
Table 8 details the part numbers for recommended fuses and fuse holders. These numbers are
provided for information only and are not available from NovAtel as separate parts.
Failure to observe the given cable construction guidelines in this section
will result in damage to the wiring (not covered by warranty).
Product
Part Description
Company
Part Number
SMART-AG mating connector
14-pin sealed receptacle
housing-black
Tyco/
AMP
776273-1
Gold plated pins for SMART-
AG connector/loose
Pins, loose piece
Tyco/
AMP
770854-3
Gold plated pins for SMART-
AG connector/strip
Pins, strip (reel)
Tyco/
AMP
770520-3
Seal Plug for unused pins on
mating connector
Seal Plug
Tyco/
AMP
770678-1