Figure 9. Crystal Connection Example
Table 6 Crystal and Circuit Requirements
Symbol
Parameter
Min
Typ
Max
Unit
F
P
Parallel resonance crystal Frequency
12
MHz
F
TOL
Frequency
Tolerance
±50 ppm
C
L
Load Capacitance for crystal parallel resonance
5
7
10
pf
DL
Crystal Drive Level
300
uW
R
BIAS
External Bias Resistor
2
MΩ
ESR Equivalent
Series
Resistance
80
Ω
Note:
FP, FTOL, CL and DL are found in the Xtal Datasheet
ESR = RM * (1 + C0/CL)/2 where RM = Motional Resistance, C0 =Shunt Capacitance from Xtal datasheet.
Datasheets may specify ESR directly – consult manufacturer if unclear whether ESR or RM are specified.
Load capacitor values (C
Lx
) can be found with formula C
L
= [(C
L1
xC
L2
)/(C
L1
+C
L2
)]+C
PCB
Or since C
L1
and C
L2
are typically of equal value, C
L
= (C
Lx
/2)+C
PCB
. or C
Lx
= (C
L
– C
PCB
) x 2