NTI NODEMUX SERIES UNIVERSAL KVM SWITCH

22

NODEMUX

SWITCH

CPU

(terminal)

RS232

First Unit

RS232

RS232

Second Unit

Last Unit

RS232
Serial Port

Matrix-Y-1

Matrix-Y-1

Matrix-Y-1

NODEMUX

SWITCH

NODEMUX

SWITCH

Disable Loopback

Disable Loopback

Enable Loopback

Loop Back

In order for an RS232 command and a response to the command to be viewed at the terminal screen, the NODEMUX must have
its Loop Back feature enabled.

More than one NODEMUX may be connected to a terminal at a time. To do so, a Matrix-Y-1 cable (available from NTI) must be
used. (See Fig. 22). For each additional NODEMUX connected, another Matrix-Y-1 cable will be required.

If the NODEMUX is one of two or more switches being controlled via RS232, and if the NODEMUX is not that last switch in the
series of switches controlled, then this setting should be changed to "DISABLED".

If the NODEMUX is the only device controlled via RS232 , or if it is the last device in a series of devices being controlled, then
this setting should remain "Enabled". (See Figure 21)


To enable or disable loop back, from the
Switch Configuration mode menu (pg. 21),

press <

Tab> until the cursor bar

moves to highlight "LOOPBACK".

Press < > (up arrow) or < > (down arrow) to
enable or disable loop back as needed for the
application.

Figure 22- Daisy chain configuration with Matrix-Y-1 cable

Unit Address

In order for a terminal to communicate with one or more NODEMUX switches, each switch must have a unique address. The
NODEMUX will only respond to commands from a terminal if its address is embedded in the command. Up to 15 NODEMUX
switches can be connected in a "daisy chain" to a terminal, each with its own unique address.

To set the address of the NODEMUX, from the Switch Configuration mode menu (Fig. 21 on page 21),
press <

Tab> until the cursor bar moves to highlight "RS232 UNIT ADDRESS".

press < > (up arrow) or < > (down arrow) until the desired address (1-15) is selected.

Exit Switch Configuration Mode

Once changes are made to the Switch Configuration menu, press <Enter> and <Y> to save them.

To exit without saving, press <Esc>, then <N>, then <Esc> again. The menu will return to the Administration Mode without
saving the changes made. .

Changes made will take effect the next time the NODEMUX is power cycled.

Note: In order to connect multiple NODEMUX units together a Matrix-Y-1 cable must be used. (See Fig. 27.) See Fig. 28
for the pinout of the Matrix-Y-1 cable.












Figure 23- RS232 connection with Matrix-Y-1 cable

NTI

SWITCH

CPU

RS232

First Unit

NTI

SWITCH

RS232

NTI

SWITCH

RS232

Second Unit

Last Unit

RS232
Serial Port

Matrix-Y-1

Matrix-Y-1

Matrix-Y-1