beautypg.com

Nortel Networks NN46200-301 User Manual

Page 24

background image

24

Appendix Electrical specifications for the AC power supply

Note the following information:

The maximum steady-state output power is limited to a total of 1140 W
for any combination of output voltages/currents at low-line 100-120 VAC
nominal input voltage conditions.

The maximum steady-state output power is limited to a total of 690 W
for any combination of output voltages/currents, excluding the 50 VDC
source at low-line 100-120VAC nominal input voltage conditions. This
limitation is required to ensure that there is sufficient PoE power or 450
W total at this input voltage condition.

The maximum steady-state output power is limited to a total of 870W
for any combination of output voltages/currents, excluding the 50 VDC
source at high-line 200-240VAC nominal input voltage conditions. This
limitation is required to ensure maximum PoE power or 900 W total for
the 50 VDC source at this input voltage condition.

To obtain the full output power rating of 1770 W, you must connect the
power supply to a nominal (200-240VAC) input voltage source.

The following table list the power specifications for the Ethernet Routing
Switch 8302AC power supply.

Table 6
Ethernet Routing Switch 8302AC power specifications

AC Input Power Ratings

Input voltage range (nominal):

100-120 VAC

200-240 VAC

Input current (nominal):

12 A

9 A

Frequency range (nominal):

50-60 Hz

50-60 Hz

Input VA

1192 VA

1768 VA

Input power consumption:

1180 W

1750 W

Heat dissipation
(thermal/output):

1126BTU/hr

1195 BTU/hr

Hold-up time:

20 ms

20 ms

DC Output Power Ratings

Max. output power (combined):

850W (760W + 90W fans)

1400 W (1310W + 90W fans)

Non-PoE:

3.3 VDC @ 150 A

3.3 VDC @ 150 A

12 VDC @ 65 A

12 VDC @ 65 A

PoE:

50 VDC @ 18 A

50 VDC @ 18 A

Fans:

12 VDC @ 7.5 A

12 VDC @ 7.5 A

Nortel Ethernet Routing Switch 8300

Installation — AC Power Supply

NN46200-301

03.01

Standard

4.0

27 August 2007

Copyright © 2007, Nortel Networks

.