beautypg.com

Table 4 8306/8310 chassis available system power – Nortel Networks NN46200-301 User Manual

Page 16

background image

16

Power supply installation

Note the following information:

If a power supply fails when you have a redundant power supply
installed, the Ethernet Routing Switch 8300 continues to operate with
no interruption of service. The chassis will continue to supply the same
module and PoE output power with the remaining power supplies. A trap
and syslog message will indicate that the configuration is non-redundant.

Nortel recommends that you operate the Ethernet Routing Switch 8300
in a redundant configuration at all times to ensure maximum network
up time.

Nortel recommends that you install each power supply on its own
dedicated branch circuit. When you plug the power cord for each power
supply into a separate AC circuit, the redundant power supply also
provides protection against the disconnection or failure of an individual
branch circuit or power supply failure.

If you have installed a redundant power supply, power available for PoE
is always determined on an N+1 redundancy. If you have 1 or 2 power
supplies in the chassis, you will be allocated PoE power equivalent to
one power supply. If you have 3 power supplies in the chassis, you will
be allocated PoE power equivalent to 2 power supplies.

Table 4
8306/8310 chassis available system power

Power
Supply

Power supply
rating

Number
of
power
supplies

Redundancy

Module

PoE

Fans

Total

1

No

600 W

450 W

90 W

1140 W

100-120VAC

2

Yes 1+1

600 W

450 W

90 W

1140 W

1140W

3

Yes 2+1

1290 W

900 W

90 W

2280 W

1

No

780 W

900 W

90 W

1770 W

200-240VAC

2

Yes 1+1

780 W

900 W

90 W

1770 W

8301AC

1770W

3

Yes 2+1

1650 W

1800 W

90 W

3540 W

1

No

535 W

225 W

90 W

850 W

100-120VAC

2

Yes 1+1

535 W

225 W

90 W

850 W

850W

3

Yes 2+1

1160 W

450 W

90 W

1700 W

1

No

860 W

450 W

90 W

1400 W

200-240VAC

2

Yes 1+1

860 W

450 W

90 W

1400 W

8302AC

1400W

3

Yes 2+1

1810 W

900 W

90 W

2800 W

Nortel Ethernet Routing Switch 8300

Installation — AC Power Supply

NN46200-301

03.01

Standard