Chapter 3

Hardware Overview

© National Instruments Corporation

3-7

NI 6115/6120 User Manual

Figure 3-5. Above-High-Level Analog Triggering Mode

In inside-region analog triggering mode, the trigger is generated when the
signal value is between the lowValue and the highValue, as Figure 3-6
shows.

Figure 3-6. Inside-Region Analog Triggering Mode

In high-hysteresis analog triggering mode, the trigger is generated when the
signal value is greater than highValue, with the hysteresis specified by
lowValue, as Figure 3-7 shows.

Figure 3-7. High-Hysteresis Analog Triggering Mode

highValue

Trigger

highValue

Trigger

lowValue

highValue

Trigger

lowValue