Specifications – TREND IMC-101 User Manual
Page 16

— 12 —
Specifications
Technology
Standards
IEEE802.3, 802.3u, Link Fault Pass-Through
Interface
RJ45 ports
10/100BaseT(X)
Fiber ports
100BaseFX (SC, ST connectors available)
LED Indicators
Power, Fault, 10/100M, Full Duplex/Collision,
Dip Switch
Port break alarm mask, 100BaseFx Full/Half
duplex selection
Alarm Contact
One relay output with current carrying capacity
of 1A @ 24 VDC
Optical Fiber
Distance
Single mode fiber for 15 km, Multi mode fiber for
2 km
Wavelength 1310
nm
Min. TX Output
-20 dBm (IMC101-M), -15 dBm (IMC101-S)
Max. TX Output
-14 dBm (IMC-101-M), -6 dBm (IMC-101-S)
Sensitivity
-36 to -32 dBm (IMC101-M), -34 to -32 dBm
(IMC101-S)
Power
Input Voltage
12 to 48 VDC; Redundant inputs
Input Current (@24V) 0.2 A
Connection
Removable Terminal Block
Overload Current
Protection
1.1 A
Reverse Polarity
Protection
Present
Mechanical
Casing
IP30 protection, aluminum case
Dimensions (W x H x
D)
53.6 x 135 x 105 mm
Weight
0.63 kg
Installation DIN-Rail,
Wall
Mounting
Environment
Operating
Temperature
0 to 60
Ƭ (32 to 140
o
F),-40 to 75
o
C (-40 to
167
o
F)
Storage Temperature -40 to 85
Ƭ (-40 to 185
o
F)
Ambient Relative
Humidity
5 to 90% (non-condensing)
Regulatory
Approvals
Safety
UL60950, UL 508, CSA C22.2 No. 60950,
EN60950
Hazardous Location
UL/cUL Class I, Division 2, Groups A, B, C and
D
ATEX Class I, Zone 2, EEx nC IIC
EMI
FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), level 3
EN61000-4-3 (RS), level 3