Chapter 7

Counters

NI 6238/6239 User Manual

7-28

ni.com

Counter n Gate Signal

The Counter n Gate signal can perform many different operations
depending on the application including starting and stopping the counter,
and saving the counter contents.

Routing a Signal to Counter n Gate

Each counter has independent input selectors for the Counter n Gate signal.
Any of the following signals can be routed to the Counter n Gate input.

RTSI <0..7>

Input PFI <0..5>

ai/ReferenceTrigger

ai/StartTrigger

ai/SampleClock

ai/ConvertClock

ao/SampleClock

PXI_STAR

In addition, Counter 1 Internal Output or Counter 1 Source can be routed to
Counter 0 Gate. Counter 0 Internal Output or Counter 0 Source can be
routed to Counter 1 Gate.

Some of these options may not be available in some driver software.

Routing Counter n Gate to an Output Terminal

You can route Counter n Gate out to any output PFI <6..9> or RTSI <0..7>
terminal. All PFIs are set to high-impedance at startup.

Counter n Aux Signal

The Counter n Aux signal indicates the first edge in a two-signal
edge-separation measurement.

Routing a Signal to Counter n Aux

Each counter has independent input selectors for the Counter n Aux signal.
Any of the following signals can be routed to the Counter n Aux input.

RTSI <0..7>

Input PFI <0..5>

ai/ReferenceTrigger