NTI NODEMUX MULTI-USER UNIVERSAL KVM SWITCH
20
RS232 CONTROL
Remote Connection
The RS232 Interface is designed to meet the RS232C standard and can be controlled from any CPU or other controller with an
RS232 communications port. The pin outs for the DB9 connector on the unit are as follows:
RS232 Connector (DB9 FEMALE)
PIN
SIGNAL
FUNCTION
1
None no
connection
2
TXD
Transmit Data (RXD at host)
3
RXD
Receive Data (TXD at host)
4
DSR
Data Set Ready
5 GND
Signal
Ground
6 DTR
Data
Terminal
Ready
7
CTS
Clear to Send
8
RTS
Request to Send
9
none no
connection
NOTE: Security must be disabled (see Administration Options on page 14) or user access granted (see System Access
List on page 15) on the port(s) to be selected by RS-232 control.
On the DB9 female connector, pins 1 (DCD), 4 (DTR), and 6 (DSR) are shorted and pins 7 (RTS) and 8 (CTS) are shorted.
Therefore, CPU handshaking is bypassed and TXD and RXD are the only active signals. A straight through DB9 cable (not null
modem) will work for most CPUs. To daisy chain multiple units, the CPU drives the input port on the first unit and the output port is
connected to the input port on the next unit etc. The last unit will have a loop back plug installed in its RS232 OUT connector.
Baud Rate
The baud rate can be changed by selecting MENU on the front panel keypad. Then select 1 for SET BAUD RATE and select the
desired baud rate of 9600, 4800, 2400 or 1200. A data protocol of 8 data bits, no parity, and 1 stop bit is used for
communications.
Unit Address and Loop Back
To allow multiple units to be controlled from a single CPU port, the RS232 control interface is designed to allow "daisy chaining"
up to 15 units. By setting the appropriate unit address with the keypad, each unit can be given a unique address (1-15). Then the
unit will only respond to commands on the bus if its address is embedded in the command.
To set the unit address using the front panel keypad (page 11),
1. Press