Fcc part 68 compliance statement – Nortel Networks Instant Internet 400 Unit User Manual
Page 7
7
Setting Up the BayStack Instant Internet 400 Unit
FCC Part 68 compliance statement
This equipment complies with Part 68 of FCC Rules. All direct connections to telephone network lines must be made
using standard plugs and jacks compliant with FCC Part 68. Please note the following:
1.
You are required to request service from the telephone company before you connect the unit to a network. When
you request service, you must provide the telephone company with the following data:
When you request T1 Service, you must provide the telephone company with:
•
The Facility Interface Code
Provide the telephone company with all the codes below:
•
04DU9-BN (1.544 MB, D4 framing format)
•
04DU9-DN (1.544 MB, D4 framing format with B8ZS coding)
•
04DU9-1KN (1.544 MB, ESF framing format)
•
04DU9-ISN (1.544 MB, ESF framing format with B8ZS coding)
The telephone company will select the code it has available.
•
The Service Order Code(s) (SOC): 6.0F
•
The required Universal Service Order Code (USOC) jack: RJ48C
When you request 56K/64K Service, you must provide the telephone company with:
•
The Facility Interface Code: 04DU5-56/64
•
The Service Order Code(s) (SOC): 6.0F
When you request 56K/64K Service, you must provide the telephone company with:
•
The Facility Interface Code: 04DU5-56/64
•
The Service Order Code(s) (SOC): 6.0F
•
The required Universal Service Order Code (USOC) jack: RJ48S
When you request V.34 Service, you must provide the telephone company with:
•
The required Universal Service Order Code (USOC) jack: RJ11C
•
The make, model number, Ringer Equivalence Number (REN), and FCC Registration number of the unit
The REN helps you determine the number of devices you can connect to your telephone line and still have all of those
devices ring when your number is called. In most, but not all, areas, the sum of the RENs of all devices should not
exceed 5.0. To be certain of the number of devices you can connect to your line, you should call your local telephone
company to determine the maximum REN for your calling area.
When you request ISDN "U" Interface Service, you must provide the telephone company with:
•
The Facility Interface Code: 02IS5
•
The Service Order Code(s) (SOC): 6.0F
•
The required Universal Service Order Code (USOC) jack: RJ49C
When you request ISDN "S/T" Interface Service, you must provide the telephone company with:
•
The Service Order Code(s) (SOC): 6.0N
•
The make, model number, and FCC Registration number of the NT1
Note the following:
•
The ISDN S/T cannot be directly connected to the network.
•
The V.35 cannot be connected to the PSTN.
•
The X.21 cannot be connected to the PSTN.