20 mhz ac electrical characteristics – National Instruments HPC167064 User Manual
Page 3

20 MHz
AC Electrical Characteristics
(See Notes 1 and 4 and
Figures 1
thru
5
) V
CC
e
5V
g
5%
T
A
e b
55 C to a125 C for HPC167064 and V
CC
e
5V
g
10%
T
A
e
0 C to a70 C for HPC467064
Symbol and Formula
Parameter
Min
Max
Units
Notes
f
C
CKI Operating Frequency
2
20
MHz
t
C1
e
1 f
C
CKI Clock Period
50
500
ns
t
CKIH
CKI High Time
22 5
ns
t
CKIL
CKI Low Time
22 5
ns
t
C
e
2 f
C
CPU Timing Cycle
100
ns
t
WAIT
e
t
C
CPU Wait State Period
100
ns
t
DC1C2R
Delay of CK2 Rising Edge after CKI Falling Edge
0
55
ns
(Note 2)
t
DC1C2F
Delay of CK2 Falling Edge after CKI Falling Edge
0
55
ns
(Note 2)
f
U
e
f
C
8
External UART Clock Input Frequency
2 5
MHz
f
MW
External MICROWIRE PLUS Clock Input Frequency
1 25
MHz
f
XIN
e
f
C
22
External Timer Input Frequency
0 91
MHz
t
XIN
e
t
C
Pulse Width for Timer Inputs
100
ns
t
UWS
MICROWIRE Setup Time
Master
100
ns
MICROWIRE Setup Time
Slave
20
t
UWH
MICROWIRE Hold Time
Master
20
ns
MICROWIRE Hold Time
Slave
50
t
UWV
MICROWIRE Output Valid Time
Master
50
ns
MICROWIRE Output Valid Time
Slave
150
t
SALE
e
t
C
a
40
HLD Falling Edge before ALE Rising Edge
115
ns
t
HWP
e
t
C
a
10
HLD Pulse Width
110
ns
t
HAE
e
t
C
a
100
HLDA Falling Edge after HLD Falling Edge
200
ns
(Note 3)
t
HAD
e
t
C
a
85
HLDA Rising Edge after HLD Rising Edge
160
ns
t
BF
e
t
C
a
66
Bus Float after HLDA Falling Edge
116
ns
(Note 5)
t
BE
e
t
C
a
66
Bus Enable after HLDA Rising Edge
116
ns
(Note 5)
t
UAS
Address Setup Time to Falling Edge of URD
10
ns
t
UAH
Address Hold Time from Rising Edge of URD
10
ns
t
RPW
URD Pulse Width
100
ns
t
OE
URD Falling Edge to Output Data Valid
0
60
ns
t
OD
Rising Edge of URD to Output Data Invalid
5
45
ns
(Note 6)
t
DRDY
RDRDY Delay from Rising Edge of URD
70
ns
t
WDW
UWR Pulse Width
40
ns
t
UDS
Input Data Valid before Rising Edge of UWR
10
ns
t
UDH
(HPC467064)
Input Data Hold after Rising Edge of UWR
20
ns
t
UDH
(HPC167064)
25
ns
t
A
WRRDY Delay from Rising Edge of UWR
70
ns
Clocks
Timers
MicrowirePlus
External
Hold
UPI
Timing
See NORMAL RUNNING MODE
This maximum frequency is attainable provided that this external baud clock has a duty cycle such that the high period includes two (2) falling edges of the CK2
clock
Note
C
L
e
40 pF
Note 1
These AC Characteristics are guaranteed with external clock drive on CKI having 50% duty cycle and with less than 15 pF load on CKO with rise and fall
times (t
CKIR
and t
CKIL
) on CKI input less than 2 5 ns
Note 2
Do not design with this parameter unless CKI is driven with an active signal When using a passive crystal circuit its stability is not guaranteed if either CKI
or CKO is connected to any external logic other than the passive components of the crystal circuit
Note 3
t
HAE
is spec’d for case with HLD falling edge occurring at the latest time can be accepted during the present CPU cycle being executed If HLD falling edge
occurs later t
HAE
may be as long as (3t
C
a
4 WS
a
72t
C
a
100) depending on the following CPU instruction cycles its wait states and ready input
Note 4
WS
e
t
WAIT
c
(number of pre-programmed wait states) Minimum and maximum values are calculated at maximum operating frequency t
c
e
20 00 MHz
with one wait state programmed
Note 5
Due to emulation restrictions
actual limits will be better
Note 6
Due to tester limitations
actual limits will be better
3