HEART RATE PRIORITY

The contact heart rate system’s ability to detect a heart

rate signal is infl uenced by several factors. Movement

of the muscles of the upper body produces an electrical

signal (muscle artifact) that will interfere with the

detection of the heart rate signal by the sensors.

Movement of the hands while they are in contact with

the sensors also produces interference. Calluses and

hand lotion act as an insulating layer to reduce the

signal strength. Also, the EKG signal generated by some

individuals is not strong enough to be detected by the

sensors. These individuals should opt for the telemetry

method of heart rate monitoring.

Contact heart rate input signals are acquired only

during contact between your hands and the stainless

steel sensors on the handrails. To use the contact heart

rate feature, place your hands around the handles so

that your hands touch both the top and the bottom of

the sensors. After the initial contact heart rate signal

is detected, the controller will enter a validation

phase requiring a good heart beat signal within 10 to

15 seconds, or until the system acquires a valid signal.

During the validation phase the controller will not

recognize telemetry heart rate signals. The controller

will display a heart icon. If, during exercise, the heart

rate displayed is erratic, it may be helpful to remove

your hands from the handles, wipe them and place them

back on the handles. In all programs, the heart rate is

shown automatically in the display window the fi rst

time the sensors are touched.

Heart Rate Priority

Both contact heart rate and telemetry (e.g., Polar®)

heart rate signal detection is available. The default

priority of heart rate input is”LOCKED INPUT.” If a

telemetry signal is detected fi rst, contact heart rate

signals are inhibited from being detected throughout the

rest of the workout session and vice-versa.

Locked/Non-Locked Heart Rate
Signal Options

When the”EITHER INPUT” option is selected the heart

rate source signal is not fi xed during the workout

session (if the signal is lost either input will be valid). If

the”LOCKED INPUTS” option is selected then the heart

rate source signal is locked on the fi rst detected signal

during the workout. To set a heart rate signal input, or

to turn off the heart rate option all together, perform the

following steps:

1. On the console keypad, press [Level: UP], [3], [2].

At this point the screen will display”HR INPUTS.”

Press [ENTER] to select this option.

2. There are fi ve options to handle heart rate input

signals. Press the [Level: UP] and [Level: DOWN]

keys to scroll through the options until you fi nd the

option that you want. Press the [ENTER] key to

select that option.

The options are as follows:

“LOCKED INPUTS“— allows either telemetry or contact

heart rate signals to be detected. Once the console has

detected a valid input signal it will lock out the opposite

type of signal for the duration of the workout session. For

example, if you start out using contact heart rate then

you are limited to using only contact heart rate during

your workout session, even if the signal is lost while

performing the workout, and vice-versa.

“EITHER INPUT”— allows either telemetry or contact

heart rate signals to be detected. Does not lock out a

particular input signal for the entire workout. Will detect

either input signal during a workout session, but only one

at a time, and only until the other signal terminates.

“TELEMETRY ONLY”— locks out contact heart rate

signals and will only detect telemetry signals.

“HAND ONLY”— locks out telemetry signals and will only

detect contact heart rate signals.

“BOTH HR OFF“— turns off the ability to detect any

heart rate signal. Used in rare situations where there is

excessive interference with the heart rate signals.

During workouts where heart rate is necessary, such as

the HR Zone Trainer and the Fitness Test, the console will

pick up telemetry heart rate signals so that the programs

are not disabled.