Environment, Safety, Electromagnetic compatibility – National Instruments PXI-1428 User Manual
Page 32
Appendix A
Specifications
© National Instruments Corporation
A-3
Weight
PCI-1428 ......................................... 0.127 kg (0.28 lb)
PXI-1428......................................... 0.172 kg (0.38 lb)
Environment
The IMAQ 1428 device is intended for indoor use only.
Operating temperature............................ 0 to 55 °C
Storage temperature ............................... –20 to 70 °C
Maximum altitude .................................. 2,000 m
Pollution Degree .................................... 2
Relative humidity ................................... 5 to 90%, noncondensing
Safety
The IMAQ 1428 meets the requirements of the following standards
for safety and electrical equipment for measurement, control, and
laboratory use:
•
EN 61010-1, IEC 61010-1
•
UL 3111-1, UL 61010B-1
•
CAN/CSA C22.2 No. 1010.1
Note
For UL and other safety certifications, refer to the product label, or visit
ni.com/hardref.nsf
, search by model number or product line, and click the
appropriate link in the Certification column.
Electromagnetic Compatibility
Emissions ............................................... EN 55011 Class A at 10 m
FCC Part 15A above 1 GHz
Immunity ................................................ EN 61326: 1997/ A2:2001,
Table 1
CE, C-Tick, and FCC Part 15 (Class A) Compliant
Note
For EMC compliance, operate this device with shielded cabling. In addition,
all covers and filler panels must be installed. Refer to the Declaration of Conformity (DoC)
for this product for any additional regulatory compliance information. To obtain the DoC