Figure 3-3. vxibus clk10 routing, Figure 3-4. smb clk10 direction – National Instruments 800 Series User Manual
Page 30
Chapter 3
VXIpc 800 Series Configuration and Installation
VXIpc 800 Series User Manual
3-6
© National Instruments Corporation
Notice that Figure 3-3b also shows switch S5. You must configure these
switches as shown when using the corresponding CLK10 source setting
of S3.
Figure 3-3. VXIbus CLK10 Routing
The VXIpc-800 can also be configured to drive the external CLK SMB
signal from the VXIbus CLK10 signal. Switch S5 controls whether the
VXIpc-800 drives or receives the external CLK SMB signal. If you
change the S5 setting to drive CLK10 out the external CLK10 SMB
connector (Figure 3-4b), do not set S3 to source CLK10 to the
backplane from the SMB; instead use the setting shown in Figure 3-3a.
Figure 3-4. SMB CLK10 Direction
S3
S3
S5
a. CLK10 Generated from Onboard
Oscillator (Default)
b. CLK10 Generated from SMB
S5
S5
a. CLK10 SMB Receives 10 MHz
Signal (Default)
b. CLK10 SMB Drives 10 MHz
Signal from VXIbus CLK10