In BCD every digit of the decimal system is represented by a 4-bit group. For example:
157

10

= 0001 0101 0111

BCD

This is not the same as binary representation. It is clear that BCD is not the most efficient
way of coding since every 4-bit group (nibble) could represent numbers 0 through 15, but
in BCD never represents numbers bigger than 9. But for some applications it is
convenient to use BCD and real time clocks are one such application.

Each 8-bit register contains two digits each represented by one nibble. Each 4-bit nibble
can represent the value of 0 up to 9 in BCD, but for some digits the maximum value to be
represented will be lower. The minute register for example will never have to count
higher than 59. The upper most digit can here be represented by 3 bits, freeing up one
bit that can be used to indicate something else.

Not all NXP real-time clocks have exactly the same register implementation and thus the
datasheet of the particular device should be consulted. As an example the register
organization of the PCF8563 is given below. Note that this is just one example and that
register organization of other types is not necessarily exactly the same.

Table 1.

Register overview PCF8563

Bit positions labelled as x are not implemented. When setting a register, also a value must be written for the ‘x’ bit positions.
When these are read back, the read back values may differ from what was previously written.
Bit positions labelled with 0 should always be written with logic 0; if read they could be either logic 0 or logic 1.

Address

Register name

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

00

HEX

control / status 1

TEST1

0

STOP

0

TESTC

0

0

0

01

HEX

control / status 2

0

0

0

TI/TP

AF

TF

AIE

TIE

02

HEX

seconds

VL

03

HEX

minutes

x

04

HEX

hours

x

x

05

HEX

days

x

x

06

HEX

weekdays

x x x x x

0

to

6>

07

HEX

months / century

C

x

x

08

HEX

years

09

HEX

minute alarm

AE

0A

HEX

hour alarm

AE

x

0B

HEX

day alarm

AE

x

0C

HEX

weekday alarm

AE

x

x

x

x

0D

HEX

CLKOUT

control

FE

x x x x x FD1

FD0

0E

HEX

timer

control

TE

x x x x x TD1

TD0

0F

HEX

timer

This manual is related to the following products: