BASICA/QuickBASIC GPIB-PC Function Calls

Section Four A

GPIB-PC User Manual

4A-8

©National Instruments Corp.

Table 4A.1 - BASICA GPIB-PC Functions (continued)

Description

CALL Function Syntax

Wait for selected event

IBWAIT (BD%,MASK%

)

Write data from string

IBWRT (BD%,WRT$)

Write data asynchronously from string

IBWRTA (BD%,WRT$)

Write data from file

IBWRTF (BD%,FLNAME$)

Write data from integer array

IBWRTI
(BD%,IARR%(0),CNT%)

Write data asynch from integer array

IBWRTIA
(BD%,IARR%(0),CNT%)

The first argument of all function calls except

IBFIND

is the integer

variable

BD%

, which serves as a unit descriptor. Refer to the

IBFIND

function description and Section Three for additional information on the
use of this unit descriptor.

Table 4A.2 contains a complete list of the QuickBASIC GPIB calls,
their parameters, and a short description of each.

Table 4A.2 - QuickBASIC GPIB-PC Calls

Description

CALL Function Syntax

Change access board of device

IBBNA (BD%,BNAME$)

Become Active Controller

IBCAC (BD%,V%)

Clear specified device

IBCLR (BD%)

Send commands from string

IBCMD (BD%,CMD$)

Send commands asynchronously from
string

IBCMDA (BD%,CMD$)

Enable/disable DMA

IBDMA (BD%,V%)

Change/disable EOS mode

IBEOS (BD%,V%)

Enable/disable END message

IBEOT (BD%,V%)

Open device and return unit descriptor

IBFIND (BDNAME$,BD%)

Go from Active Controller to standby

IBGTS (BD%,V%)

Set/clear ist

IBIST (BD%,V%)

Go to local

IBLOC (BD%)

Place device online/offline

IBONL (BD%,V%)

Change primary address

IBPAD (BD%,V%

)