beautypg.com

Tfa9812, Nxp semiconductors – NXP Semiconductors TFA9812 User Manual

Page 46

background image

TFA9812_2

© NXP B.V. 2009. All rights reserved.

Preliminary data sheet

Rev. 02 — 22 January 2009

46 of 66

NXP Semiconductors

TFA9812

BTL stereo Class-D audio amplifier with I

2

S input

[1]

I

P

is the current through the analog supply voltage (V

DDA

) pin added to the current through the power supply voltage (V

DDP

) pin.

[2]

Thermal foldback temperature sensor is not located at hottest spot. Hottest spot is 12

°

C higher.

[3]

Current limiting concept: in overcurrent condition no interruption of the audio signal in case of impedance drop.

[4]

PLL output frequency not external available.

Thermal Foldback (TF)

T

act(th_fold)

thermal foldback
activation
temperature

[2]

118

125

132

°

C

OverTemperature Protection (OTP)

T

act(th_prot)

thermal protection
activation
temperature

-

-

160

°

C

OverVoltage Protection (OVP)

V

P(ovp)

overvoltage
protection supply
voltage

20

22.3

24

V

UnderVoltage Protections (UVP)

V

P(uvp)

undervoltage
protection supply
voltage

UVP on V

DDA

7

7.5

8

V

UVP on V

DDA(3V3)

1.6

2.2

3.0

V

OverCurrent Protection (OCP)

I

O(ocp)

overcurrent
protection output
current

[3]

3.0

3.3

3.6

A

Window Protection (WP)

V

o

output voltage

high level

-

V

DDA

1

-

V

low level

-

REFA + 1

-

V

OverFrequency Protection (OFP)

f

OFP

Overfrequency
protection frequency

At PLL output frequency

[4]

100

140

185

MHz

UnderFrequency Protection (OFP)

f

UFP

Underfrequency
protection frequency

At PLL output frequency

[4]

30

45

60

MHz

Table 55.

DC characteristics

…continued

Unless specified otherwise, V

DDA

= V

DDP

= 12 V, V

SSP1

= V

SSP2

= 0 V, V

DDA(3V3)

= V

DDD(3V3)

= 3.3 V,

V

SS1

= V

SS2

= REFD = REFA = 0 V, T

amb

= 25

°

C, R

L

= 8

, f

i

= 1 kHz, f

s

= 44.1 kHz, f

sw

= 400 kHz, 24-bit I

2

S input data,

MCLK clock mode, typical application diagram (

Figure 13

).

Symbol

Parameter

Condition

Min

Typ

Max

Unit