beautypg.com

11 invalid bck protection, 12 dc blocking, 13 overview protections – NXP Semiconductors TFA9812 User Manual

Page 26: Section 8.7.11, Tfa9812, Nxp semiconductors

background image

TFA9812_2

© NXP B.V. 2009. All rights reserved.

Preliminary data sheet

Rev. 02 — 22 January 2009

26 of 66

NXP Semiconductors

TFA9812

BTL stereo Class-D audio amplifier with I

2

S input

8.7.11 Invalid BCK protection

The BCK clock signal is verified as being at one of the allowed relative frequencies: 32 f

s

,

48 f

s

or 64 f

s

. If it is not at one of these frequencies the TFA9812 will set the output stages

to 3-state mode to prevent audible effects.

The MCLK clock signal is also verified as being valid, see

Section 8.2.3

.

Detection of violation results in an automatic internal overruling of the MCLK assignment
to BCK.

8.7.12 DC blocking

The TFA9812 features a high pass filter after the I

2

S input to block DC signals. DC values

at the output can damage the peripheral devices. The high pass filter is always enabled.

8.7.13 Overview protections

Table 21

shows the overview of the protections.

Table 21.

Overview protections

Protections

Symbol Conditions

DIAG
pin

I

2

C

flag

[1]

Output

Recovering

TF

programmable
max. T

j

> 125

°

C

Floating

-

Switching

Automatic, increasing
volume control back to
volume setting

OTP

T

j

> 160

°

C

LOW

DIAG

Floating

Automatic, after 1

µ

s and

T

j

< 160

°

C

OCP

I

O

> I

ORM

LOW

DIAG

Floating

Automatic, after 1

µ

s and

I

O

< I

ORM

OVP

V

DDA

> 20 V

LOW

DIAG

Floating

Restart (fault to operating
when V

DDA

> 8 V and

V

DDA(3V3)

> 3 V)

UVP

V

DDA

< 8 V or

V

DDA(3V3)

< 3 V

LOW

DIAG

Floating

Restart (fault to operating
when V

DDA

> 8 V and

V

DDA(3V3)

> 3 V)

ODP

T

j

> 140

°

C and I

O

> I

ORM

LOW

DIAG

Floating

Restart (fault to operating
when T

j

< 140

°

C or

IO < I

ORM

)

WP

[2]

OUTX > V

DDA

1 V or

OUTX < REFA + 1 V

LOW

DIAG

Floating

Restart (fault to operating
when OUTX < V

DDA

1 V

and OUTX > V

SSA

+ 1 V)

LP

PLL out of lock

Floating

LP

Floating

Restart (fault to operating
when PLL is in lock)

UFP

PLL frequency < 45 MHz

Floating

UFP

Floating

Restart (fault to operating
when