IR Connections for a System with a Dedicated Preamp/Receiver and up to six MRZ-6’s
As explained on page 7, a single zone system can be expanded to distribute a single source to up to 36 rooms using
six MRZ-6 units. See Figure 17
• A 12VDC wall adapter is connected to the switched outlet of the Preamp/Receiver to provide sync (or sta-
tus) to the first (or Master) MRZ-6. This switched outlet may also be used to power up source components
which have latching power.
• The UART connection enables the Slave MRZ-6’s to power on the Preamp/Receiver using the automation
codes taught to the Master MRZ-6. The UART connection also enables All On and All Off control of all the
rooms in the system. See page 20 of the MRZ-6 manual.
• DATA OUT of the Slave MRZ-6’s is connected to the DATA IN of the Master via the DATA IN and DATA
OUT jacks. See Figure 15.
• Only the Master MRZ-6’s Dedicated flasher output is connected to the Preamp/Receiver’s front panel IR
sensor.
• When using RP-9 keypads, all automation codes are taught to the Master MRZ-6 only.
For more information concerning IntelliPad®/MRZ-6 programming, see page 26 of the MRZ-6 manual.
• Both ZONE DIP switches should be set to the UP (or single zone) position. IR codes received at any of the
MRZ-6’s sensor inputs are passed through DATA IN and DATA OUT terminals and output via the Master
MRZ-6’s Dedicated and Common flasher outputs.
12
0 1 0 : 0 0
O O : 0 0
O O : 0 0
93.9 FM
STEREO
COMMON
ZONE
ALL ON
CTRL
OUT
POWER
16VAC
FLASHER
LEVEL
ADJUST
1
G
N
D
D
A
T
A
+
1
2
V
2
G
N
D
D
A
T
A
+
1
2
V
3
G
N
D
D
A
T
A
+
1
2
V
4
G
N
D
D
A
T
A
+
1
2
V
5
G
N
D
D
A
T
A
+
1
2
V
6
G
N
D
D
A
T
A
+
1
2
V
IN
OUT
FLASHERS
IR DATA
DEDI-
CATED
12V
SYNC
IR SENSOR/KEYPAD INPUTS
V E
UART
+ -
MAIN
INPUT
ROOM 1
OUTPUT
ROOM 2
OUTPUT
ROOM 3
OUTPUT
ROOM 4
OUTPUT
ROOM 5
OUTPUT
ROOM 6
OUTPUT
L
R
L
R
L
R
L
R
CASCADE
OUTPUT
L
R
L
R
L
R
L
R
Niles Audio Corporation, Inc.
Miami, Florida USA
MODEL MRZ-6
This device complies with part 15 of the FCC Rules. Operation is sub-
ject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
COMMON
ZONE
ALL ON
CTRL
OUT
POWER
16VAC
FLASHER
LEVEL
ADJUST
1
G
N
D
D
A
T
A
+
1
2
V
2
G
N
D
D
A
T
A
+
1
2
V
3
G
N
D
D
A
T
A
+
1
2
V
4
G
N
D
D
A
T
A
+
1
2
V
5
G
N
D
D
A
T
A
+
1
2
V
6
G
N
D
D
A
T
A
+
1
2
V
IN
OUT
FLASHERS
IR DATA
DEDI-
CATED
12V
SYNC
IR SENSOR/KEYPAD INPUTS
V E
UART
+ -
MAIN
INPUT
ROOM 1
OUTPUT
ROOM 2
OUTPUT
ROOM 3
OUTPUT
ROOM 4
OUTPUT
ROOM 5
OUTPUT
ROOM 6
OUTPUT
L
R
L
R
L
R
L
R
CASCADE
OUTPUT
L
R
L
R
L
R
L
R
Niles Audio Corporation, Inc.
Miami, Florida USA
MODEL MRZ-6
This device complies with part 15 of the FCC Rules. Operation is sub-
ject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Figure 17 IR Connections for a System with a Dedicated Preamp/Receiver and up to six MRZ-6’s
From tape or pre-out
Master MRZ-6
Slave MRZ-6
To switched outlet