beautypg.com

Paxar Monarch 9433 User Manual

Page 17

background image

Using Diagnostics 2-5

3. Select Grey Scale.

A grey scale label prints to check the uniformity of the printing.
You return to the Test Label menu.

The test sample should be uniformly grey across the supply. If
you see voids, especially on the edges, save your sample and call
Service.

Note: You may receive a "Memory Full" error if you are using MPCL

because you need to reallocate memory. Refer to the
Programmer's Manual for more information.

4. Select MIF Info.

MIF stands for Monarch Initialization Files. MIF files specify
parameters for the printer.

A test label prints displaying the settings for the printer. The line
beginning with SWID indicates if a custom MIF file is loaded.
If there is no MIF file, you will see “No MIF” and you will not get a
test print.

You return to the Test Label menu.

5. Press

F to return to the Diagnostics menu.

Label w ith voids