9
OEM650/OEM650X • INSTALLATION
Jumper #1 Installed
Jumper #1 Removed
Current Resistance
Current Resistance
Current Resistance
(Amps)
(Ohms)
(Amps)
(Ohms)
(Amps)
(Ohms)
2.0
0
Ω
1.3
7.32 k
Ω
0.7
0
Ω
1.9
787
Ω
1.2
8.87 k
Ω
0.6
2.21 k
Ω
1.8
1.62 k
Ω
1.1
10.7 k
Ω
0.5
5.36 k
Ω
1.7
2.49 k
Ω
1.0
13.0 k
Ω
0.4
10.0 k
Ω
1.6
3.57 k
Ω
0.9
15.4 k
Ω
0.3
16.2 k
Ω
1.5
4.64 k
Ω
0.8
18.2 k
Ω
0.2
27.4 k
Ω
1.4
5.90 k
Ω
0.7
21.5 k
Ω
Table 2-9.
OEM350/350X
Resistor Selection for Motor Current
6. Connect a 24VDC - 75VDC power supply to
VDC+
and
VDC
-.
Refer to Figure 2-5 for a diagram of this connection and the
complete OEM650 test configuration.
OEM
s
e
r
i
e
s
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
POWER
FAULT
Power
Supply +
-
Refer to Figures 2-2 and
2-3 for specific motor
wiring instructions
OEM
Series
Motor
Figure 2-5. OEM650 Test Configuration
WARNING
Reversing VDC+ and VDC- can seriously damage the drive.
7. Apply power. The OEM’s green power LED should be on. If the
red
FAULT
LED is on, consult Chapter 4, Troubleshooting. After
verifying that the motor moves CW and CCW, turn off power.
❐ Disconnect cables and resistor.
❐ Snap off cover.
❐ Install jumper 11.
❐ Replace cover.