INSTALLATION • OEM650/OEM650X
6
3. Slide the drive cover back on.
4. Attach the motor (to A+, A-, B+, B-). Do not connect the motor to
the load at this time (refer to Figure 2-2 for 23 size motors or
Figure 2-3 for 34 size motors). OEM size 23 motors may be wired
in a series or parallel configuration. If you are using a 75VDC
power supply (OEM300) with the drive or drive indexer, Compumo-
tor recommends that you use a series configuration, however; a
parallel configuration should be used when the power supply is
24VDC - 48VDC. Parallel configurations will cause the drive to
dissipate slightly more heat than a serial configuration. This
increase in drive temperature will not affect the unit's performance,
but it may adversely affect heat-sensitive devices that are stored
within the same enclosure.