Philips indoor luminaires

11.8

LMM Modules

Lighting controls

Product ID

Description

EOC

LRC5913/10 CONTR 9x4 PLUG 3 SW

GST-conn: 3 pole, EM-test: no, Dimming: no

731032 99

LRC5914/10 CONTR 9x4 PLUG 4 SW

GST-conn: 4 pole, EM-test: no, Dimming: no

731049 99

LRC5923/10 CONTR 9x4 PLUG 3 SW&RE

GST-conn: 3 pole, EM-test: no, Dimming: 1-10V

731056 99

LRC5924/10 CONTR 9x4 PLUG 4 SW&RE

GST-conn: 3 pole, EM-test: yes, Dimming:1-10V

731063 99

LRC5933/10 CONTR 9x4 PLUG 3 DIG

GST-conn: 3 pole, EM-test: no, Dimming: DALI/DSI

731070 99

LRC5934/10 CONTR 9x4 PLUG 4 DIG

GST-conn: 4 pole, EM-test: yes, Dimming: DALI/DSI

731087 99

LRC5944/10 CONTR 9x4 PLUG 4 DIGSW

GST-conn: 4 pole, EM-test: yes, Dimming: DALI/DSI

731124 99

DIN-rail unit with 4 separate outputs
(Switching & Regulating [1-10 V]) able
to switch a load of 5 A each to control
luminaires directly or via contactors
in the cabinet to switch higher lighting
loads.

Product ID

EOC

LRC5423/10 CONTR 4X0 DIN

SW&RE

731100 99

LRC5423

Input unit with 4 sensor interfaces
(light sensors, movement detectors and
infrared [IR] receivers) and 4 inputs
for standard wall switches/emergency
test sensors. DIN-rail unit, which is also
suitable for use as an installation box,
i.e. this unit does not require an outer
enclosure.

Product ID

EOC

LRC5059/00 CONTR 0x4 SENSR

& SW DIN

730240 00

LRC5059

DALI Lighting Control Module in a
DIN-rail housing with 1 DALI output.
This controller can switch and regulate
up to 64 DALI devices. The DALI
devices can be controlled separately
or in groups. The unit has inputs for
sensors and switches, but is designed
to work in combination with the
4SI input unit for sensors.The use of

sensors and the maximum numbers of
separate DALI groups depend on the
application (refer to the datasheet for
more information).

Product ID

EOC

LRC5141/10 CONTR 16x2 DIN

DALI

731117 99

LRC5141/5143

A range of Lighting Control Modules
(LCM) with 9 outputs, 4 sensor interfaces
(light sensors, movement detectors and
infrared [IR] receivers) and 4 inputs for
standard wall switches and emergency
test sensors. All inputs and outputs and
network connections are plug-and-socket
for easy and secure installation. The
outputs are fused: one fuse (5 A) to each
of the three sides.

LRC5913

The LCMs use Wieland GST connectors,
either 3 pole or 4 pole with a permanent
supply for emergency luminaires.
The LCMs are upgradeable from non-
dimming to dimming by exchanging the
logic module. This can be done while
the power module remains installed.
The LRC5944 has three outputs that
can be configured to either DALI/DSI or
(mains) switching only.