11.8
LMM Modules
Lighting controls
Product ID
Description
EOC
LRC5913/10 CONTR 9x4 PLUG 3 SW
GST-conn: 3 pole, EM-test: no, Dimming: no
731032 99
LRC5914/10 CONTR 9x4 PLUG 4 SW
GST-conn: 4 pole, EM-test: no, Dimming: no
731049 99
LRC5923/10 CONTR 9x4 PLUG 3 SW&RE
GST-conn: 3 pole, EM-test: no, Dimming: 1-10V
731056 99
LRC5924/10 CONTR 9x4 PLUG 4 SW&RE
GST-conn: 3 pole, EM-test: yes, Dimming:1-10V
731063 99
LRC5933/10 CONTR 9x4 PLUG 3 DIG
GST-conn: 3 pole, EM-test: no, Dimming: DALI/DSI
731070 99
LRC5934/10 CONTR 9x4 PLUG 4 DIG
GST-conn: 4 pole, EM-test: yes, Dimming: DALI/DSI
731087 99
LRC5944/10 CONTR 9x4 PLUG 4 DIGSW
GST-conn: 4 pole, EM-test: yes, Dimming: DALI/DSI
731124 99
DIN-rail unit with 4 separate outputs
(Switching & Regulating [1-10 V]) able
to switch a load of 5 A each to control
luminaires directly or via contactors
in the cabinet to switch higher lighting
loads.
Product ID
EOC
LRC5423/10 CONTR 4X0 DIN
SW&RE
731100 99
LRC5423
Input unit with 4 sensor interfaces
(light sensors, movement detectors and
infrared [IR] receivers) and 4 inputs
for standard wall switches/emergency
test sensors. DIN-rail unit, which is also
suitable for use as an installation box,
i.e. this unit does not require an outer
enclosure.
Product ID
EOC
LRC5059/00 CONTR 0x4 SENSR
& SW DIN
730240 00
LRC5059
DALI Lighting Control Module in a
DIN-rail housing with 1 DALI output.
This controller can switch and regulate
up to 64 DALI devices. The DALI
devices can be controlled separately
or in groups. The unit has inputs for
sensors and switches, but is designed
to work in combination with the
4SI input unit for sensors.The use of
sensors and the maximum numbers of
separate DALI groups depend on the
application (refer to the datasheet for
more information).
Product ID
EOC
LRC5141/10 CONTR 16x2 DIN
DALI
731117 99
LRC5141/5143
A range of Lighting Control Modules
(LCM) with 9 outputs, 4 sensor interfaces
(light sensors, movement detectors and
infrared [IR] receivers) and 4 inputs for
standard wall switches and emergency
test sensors. All inputs and outputs and
network connections are plug-and-socket
for easy and secure installation. The
outputs are fused: one fuse (5 A) to each
of the three sides.
LRC5913
The LCMs use Wieland GST connectors,
either 3 pole or 4 pole with a permanent
supply for emergency luminaires.
The LCMs are upgradeable from non-
dimming to dimming by exchanging the
logic module. This can be done while
the power module remains installed.
The LRC5944 has three outputs that
can be configured to either DALI/DSI or
(mains) switching only.