Sensaphone, Cause solution – Phonetics 1108 User Manual
Page 98
Sensaphone
®
Model 1108 User’s Manual
86
Communications / Dial-out:
Problem
1.
The Model 1108 f
ails to dial out.
a)
The telephone number may be
incorrectly programmed.
b)
T
one or pulse (the current dialing
method) is not compatible with the
telephone line on which the Model 1108
is installed.
c)
Recognition
T
ime is too long.
An alert
condition does not remain in ef
fect long
enough to become a valid alarm.
Cause
Solution
Recheck programming steps,
Refer to
Chapter 4, Section 4.2.1.
Switch from the current setting: from tone to
pulse, or from pulse to tone. Refer to
Chapter 4, Section 4.3.
Reprogram Recognition
T
ime. Set the
Recognition
T
ime to the minimum duration
required to create a valid alarm. If possible,
test the new setting by deliberately creating
an alert condition. Refer to Chapter 5,
Section 5.3.
d
)
Max Calls is set to zero.
Reprogram Max Calls. It is a good idea to
set your Max Calls to at least equal the
number of dial-out telephone numbers
programmed. Refer to Chapter 4,
Section 4.12.1.