Sensaphone – Phonetics 1108 User Manual
Page 104
Sensaphone
®
Model 1108 User’s Manual
92
Other Monitoring:
Cause
Solution
Problem
1
.
The batteries drain prematurely
.
The batteries will take over powering the
unit when the AC transformer is unplugged
from the 120
V
A
C outlet.
When storing the
unit, be sure to remove the batteries. Refer
to Chapter 2, Section 2.4.
Be sure to use alkaline batteries
—
do not use
rechar
geable nicad batteries.
If the solutions of
fered abo
v
e do not appear to correct the problem, apply the follo
wing steps, in the order sho
wn.
•
Remove the batteries.
•
Unplug the unit.
•
W
ait one minute for the Model 1108 to completely po
wer do
wn.
•
Plug in the unit's
A
C
adaptor into a standard 120
V
A
C outlet.
•
Replace the batteries.
•
Reconfigure the inputs. Refer to Chapter 5, Section 5.1.
Refer to Chapter 2, Installation, for additional information on batteries and installation procedures.
The unit
’s
A
C
transformer is unplugged or
for some other reason, full AC power is not
available to the unit.