beautypg.com

Error status – Polycom SpectraLink 1725-36033-001 User Manual

Page 42

background image

SpectraLink 8000 SVP Server: Administration Guide for SIP

42

PN: 1725-36033-001_G.doc

system function and to troubleshoot areas that may be experiencing

trouble.

Error Status

The

Error Status

screen displays any alarms that indicate some system

malfunction. Some of these alarms are easily remedied and others

require a call to Polycom’s Customer Support Department.
From the

System Status Menu,

select

Error Status

. The screen displays

active alarms on the SVP Server.
The following table displays the list of alarms and a description of the

action to take to eliminate the alarm.

Alarm Text

Action

Maximum payload usage reached

Reduce usage, clear alarm

2

Maximum telephone usage reached

Reduce usage, clear alarm

Maximum access point usage reached

Reduce usage, clear alarm

Maximum call usage reached

Reduce usage, clear alarm

SRP audio delayed

Reduce usage, clear alarm

SRP audio lost

Reduce usage, clear alarm

No IP address

Configure an IP address

SVP Server(s) lost

Reduce usage or replace lost
SVP Server. Clear alarm

Press C to clear all clearable alarms.


2

If capacity problems persist, additional SVP Servers may need to be added to the system to improve performance.