background image

Programming Reference

Alarm Settings

Revised April 2000

DBS-EX23-530

4-19

Slip Alarms

Slip Counter

FF1 9# 4# 4# 3# 2# (0-9000)#

FF1 9# 4# 5# 3# 2# (0-9000)#

Error counter for the Slip FF key.

Signal Loss Alarms

Loss of Signal Counter

FF1 9# 4# 4# 3# 4# (0-9000)#

FF1 9# 4# 5# 3# 4# (0-9000)#

Error counter for the Signal Loss FF key.

Sync Loss Alarms

Sync Loss Counter

FF1 9# 4# 4# 3# 5# (0-9000)#

FF1 9# 4# 5# 3# 5# (0-9000)#

Error counter for the Sync Loss FF key.

Sync Loss Relay

FF1 9# 4# 4# 4# 3# (0-1)#

FF1 9# 4# 5# 4# 3# (0-1)#

Determines if the alarm relay on the ISDN
MDF card closes in the event of sync loss
alarms.

Relay Control

Relay Reset

FF1 9# 4# 4# 4# 6# (0-1)#

FF1 9# 4# 5# 4# 6# (0-1)#

Determines whether the alarm relay is cleared
manually or automatically.

Parameter

Address

Function