beautypg.com

Sw1-6/7 clock mode, Sw1-8 rdl function, Sw1-6/7 clock mode sw1-8 rdl function – Patton electronic 1082/F User Manual

Page 15

background image

15

SW1-6/7 Clock Mode.

Use Switches S1-6 and S1-7 to configure the

1082 or Model 1082/144 for internal, or receive recover clock mode.

Note

Placing SW1-6 and SW1-7 in the OFF mode performs reset of

the hardware/software.

SW1-8 RDL Function.

Use Switch S1-8 to allow Model 1082/F to enter

the Remote Digital Loopback diagnostic test when requested to do so by
the far end Modem. For example, when switch S1-8 is set to “ON”, it will
enter RDL mode when requested to do so by the remote Model 1082.

S1-6

S1-7

Description

ON

ON

Internal clock (DEFAULT)

ON

OFF

Recover clock

OFF

ON

Network clock

OFF

OFF

Hardware/software reset

ON

Respond to RDL (DEFAULT)

OFF

Response to RDL disabled