Configuring dip switch s1 – Patton electronic 1082/F User Manual

Page 13

background image

13

Figure 5.

DIP switches

Figure 5 shows the orientation of the DIP switches in the “ON” and “OFF”
positions.

Configuring DIP Switch S1

DIP switch S1 is where you configure the units for Octet or clear channel
timing, enabling or disabling the front panel switches, SNMP control
enable or disable, Clock mode, and RDL enable or disable.

The following table summarizes default positions of DIP switches S1-1
through S1-8. Detailed descriptions of each switch follow Table 1.

Table 1:

DIP Switch Summary Table

Position

Function

Factory Default

S1-1

Octet or Clear Channel

Mode

ON—Clear Channel

S1-2

SNMP Hardware/Soft-

ware Control

OFF—Hardware control (DEFAULT)

S1-3

Front Panel Switch

Function

OFF—Front Panel Switches Enabled

S1-4

SNMP Control

ON—Enables SNMP control of 1082

S1-5

Reserved

OFF

S1-6

Clock Mode

ON—Internal Clock

S1-7

ON

S1-8

RDL Function

ON—Respond to RDL