602 Specification Table: Standard Product — FE and QFE 4.3KVA-18KVA

Model

4.3KVA/3kW

5.3KVA/3.7kW

7KVA/5kW

10KVA/7.5kW

12.5KVA/10kW

18KVA/15kW

AC Input Voltage
and Current,
Standard Charger


FE:


QFE:

100 = 38 amps
120 = 32 amps*
200 = 19 amps
208 = 18 amps
220 = 17 amps
240 = 16 amps
220 = 19 amps
230 = 18 amps
240 = 17 amps
380 = 11 amps
400 = 10 amps
415 = 9 amps

100 = 46 amps
120 = 38 amps*
200 = 23 amps
208 = 22 amps
220 = 21 amps
240 = 19 amps
220 = 21 amps
230 = 20 amps
240 = 19 amps
380 = 13 amps
400 = 12 amps
415 = 11 amps

100 = 58 amps
120 = 51 amps*
200 = 29 amps
208 = 30 amps
220 = 27 amps
240 = 26 amps
220 = 27 amps
230 = 26 amps
240 = 24 amps
380 = 16 amps
400 = 15 amps
415 = 14 amps



200 = 45 amps
208 = 45 amps
220 = 41 amps
240 = 39 amps
220 = 43 amps
230 = 41 amps
240 = 39 amps
380 = 25 amps
400 = 24 amps
415 = 23 amps



200 = 59 amps
208 = 58 amps
220 = 53 amps
240 = 50 amps
220 = 55 amps
230 = 53 amps
240 = 51 amps
380 = 33 amps
400 = 31 amps
415 = 30 amps



200 = 85 amps
208 = 86 amps
220 = 81 amps
240 = 76 amps
220 = 81 amps
230 = 78 amps
240 = 75 amps
380 = 48 amps
400 = 46 amps
415 = 44 amps

Recommended Input
Service for 60 Hz
Models**

120 = 40 amp*
208 = 25 amp
240 = 20 amp

120 = 50 amp*
208 = 30 amp
240 = 25 amp

120 = 65 amp*
208 = 40 amp
240 = 35 amp

208 = 60 amp
240 = 50 amp

208 = 75 amp
240 = 65 amp

208 = 115 amp
240 = 100 amp

Output Voltage and
Maximum Output
Current in amps***


FE:


QFE:

100 = 42 amps
120 = 34 amps
200 = 21 amps
208 = 20 amps
220 = 19 amps
240 = 17 amps
220 = 19 amps
230 = 18 amps
240 = 17 amps

100 = 52 amps
120 = 44 amps
200 = 26 amps
208 = 26 amps
220 = 24 amps
240 = 22 amps
220 = 23 amps
230 = 22 amps
240 = 21 amps

100 = 68 amps
120 = 58 amps
200 = 34 amps
208 = 34 amps
220 = 31 amps
240 = 29 amps
220 = 31 amps
230 = 30 amps
240 = 28 amps

100 = 98 amps
120 = 82 amps
200 = 49 amps
208 = 48 amps
220 = 46 amps
240 = 41 amps
220 = 45 amps
230 = 43 amps
240 = 41 amps

100 = 124 amps
120 = 103 amps
200 = 62 amps
208 = 58 amps
220 = 55 amps
240 = 51 amps
220 = 56 amps
230 = 52 amps
240 = 51 amps

100 = 176 amps
120 = 149 amps
200 = 88 amps
208 = 84 amps
220 = 82 amps
240 = 73 amps
220 = 84 amps
230 = 76 amps
240 = 73 amps

Efficiency On AC
Line

90%

90%

90%

90%

91%

92%

On Line BTU/hour:

KW/hour:

1138
.333

1403
.411

1896
.556

2844
.833

3375
.989

4452
1.3

Audible Noise (dB)

50

51

52

55

56

57

Runtime (minutes)

Full Load:
Half Load:

10
24

20
50

12
33

11
26

18
48

10
26

Weights:
Without Battery

60 Hz Units
50 Hz Units

With Battery****

60 Hz Units
50 Hz Units

N Cabinet with
Standard Batteries

243 lbs.
115.7 kgs.

348 lbs.
163.3 kgs.

268 lbs.
131.1 kgs.

484 lbs.
229.1 kgs.

362 lbs.
176.5 kgs.

578 lbs.
274.4 kgs.

442 lbs.
217.7 kgs.


395 lbs.
(179.2 kgs.)

505 lbs.
251.3 kgs.


535 lbs.
(242.7 kgs.)

625 lbs.
312.1 kgs.


675 lbs.
(306.2 kgs.)

Dimensions
(H x W x D)

29.5 in. x 15.5 in. x 25 in.
750 mm x 395 mm x 635 mm

NOTE: If your model has an internal

bypass switch, add 8 in. or
200 mm to the depth.

36.5 in. x 19 in. x 32 in.
930 mm x 485 mm x 815 mm

NOTE: If your model has an internal bypass switch, add 8 in. or 200 mm to

the depth.

* FE 4.3KVA, 5.3KVA and 7KVA models have optional 120 VAC input voltage.
** Size input protection according to all applicable local or national codes. Fuse and circuit breaker sizes vary. Sizes shown are for the U.S. and
Canada.
***At 0.7 to 0.83 leading power factor.
****FE and QFE 10KVA, 12.5KVA and 18KVA models do not have internal batteries. Batteries are in a separate battery cabinet or rack.