2 - 1 5

1. Cursor to the desired sub-code area and press the ENTER button.

The sub-code area toggles and appears in inverse video if S/PDIF
is selected, or in normal video if AES/EBU is selected.

2. Set the output switches on the AES/EBU Cards and on the DA7’s

Rear Panel to the same position that the respective sub-code area
is selected to in the DIGITAL OUTPUT SELECT within the [D-IO
INPUT SET] window. These switches set only the electrical
differences of RS-422/110

for AES/EBU or 0.5 V/75

for S/PDIF,

while the sub-code areas select the sub-code data in the output
signals. Therefore, for proper operation, the output switch and
the sub-code area for must be in the same position.

37. All Control Change Numbers are available for MIDI Remote mode.

Previous Versions: You could not select MIDI Control Change numbers 6,
38, 96, 97, 98, 99, 100 or 101. They had been reserved by the DA7 operating
system.

Version 2.0: You can now select any Control Change Number up to 119.